background image

Jetter AG

Programming | 7

JX3-THI2-RTD-EI User Manual

21 / 36

I/O numbering system

Inputs or outputs of the module are directly accessed via I/O numbers. The I/O
numbers consist of prefix 1, the GNN, prefix 2, the module position in the system
and the module-specific I/O number.

Fig. 14: 

Example: 

I/O numbers

Digits

Description

Value range

1

Prefix 1

NNN

Bus node ID, GNN

001 … 199

01

Prefix 2

XX

Position of the module within the
station

02 … 17

ZZ

Module-specific I/O number

01 … 16

Содержание JX3-THI2-RTD-EI

Страница 1: ...User Manual JX3 THI2 RTD EI We automate your success...

Страница 2: ...the original User Manual Revision 2 04 1 Date of issue 8 6 2019 This document has been compiled by Jetter AG with due diligence and based on the known state of the art Revisions and further developmen...

Страница 3: ...ate 8 3 5 Scope of delivery 9 4 Technical specifications 10 4 1 Dimensions 10 4 2 Environmental conditions 10 4 3 Electrical properties 11 4 4 Temperature inputs 11 4 5 Mechanical specifications 11 4...

Страница 4: ...sters 22 8 3 Module state 22 8 4 Temperature inputs 23 8 5 Temperature inputs Command registers 24 8 6 Temperature input status 25 8 7 Force value 26 8 8 Averaging 27 8 9 Monitoring limit values 27 8...

Страница 5: ...pdating service Start Jetter We automate your success For further information refer to the following information products Version updates Information about new versions of software products or of the...

Страница 6: ...ion in accordance with this man ual SELV The operating voltage of this device is classified as Safety Extra Low Voltage and is therefore not subject to the European Low Voltage Directive 2 2 2 Usage o...

Страница 7: ...for temperature measurement with PT100 PT1000 sensors 3 1 Design 1 4 3 2 1 5 8 7 6 Fig 1 Design of the device 1 DIN rail latch 2 Housing 3 Backplane module 4 Connectors for expansion mod ules 5 DIN ra...

Страница 8: ...urce of information to analyze problems Diagnostics capabilities are also offered in the Setup window of the JetSym soft ware LED Flashing pat tern Color Description R OFF No logic circuit supply ON G...

Страница 9: ...User Manual 9 36 3 5 Scope of delivery Scope of delivery Item number Quantity JX3 THI2 RTD EI 10001062 1 Male connector in spring cage technology 10 pin 60869252 2 Terminal labels 60870411 10 Keying...

Страница 10: ...ty 10 95 non condensing DIN EN 60068 2 2 Max operating altitude 2 000 m above sea level Corrosion immunity and chemical resistance No special protection against corrosion Ambient air must be free from...

Страница 11: ...ement in approx 10 ms Fast Mode Measurement in approx 100 ms Resolution of measurements The measurement resolution is influenced by various factors Conversion time Slow Mode min 20 fold averaging ambi...

Страница 12: ...ted to chassis ground internally Overvoltage category II Tab 5 Electrical safety Emitted interfer ence Parameter Values Standard Frequency band 30 230 MHz DIN EN 61000 6 3 DIN EN 61131 2 DIN EN 55011...

Страница 13: ...5 0 5 kV Surge voltages asymmetric line to earth Common mode interference tr th 1 2 50 s DIN EN 61131 2 DIN EN 61000 6 2 DIN EN 61000 4 5 0 5 kV Tab 8 DC power supply inputs and outputs 4 6 3 Shielde...

Страница 14: ...cal position on the DIN rail Keep the minimum distance to surrounding parts 1 2 3 3 Fig 5 Installing the expansion module on the DIN rail 1 DIN rail 2 Upper DIN rail latch 3 Minimum distance to surrou...

Страница 15: ...DIN rail The release latch lets you remove the device from the DIN rail 2 A A 1 Fig 6 Dismounting example 1 DIN rail 2 DIN rail release latch A Detail view 1 Disconnect the system from the power supp...

Страница 16: ...IP20 is not guaranteed when replacing JX3 modules If you touch the EMC clip you may damage this clip A damaged clip may impair noise immunity Do not touch any electronic components after removing the...

Страница 17: ...U1 Voltage path to sensor 1 U2 Voltage path to sensor 2 U1 Voltage path to sensor 1 U2 Voltage path to sensor 2 I1 Current path to sensor 1 I2 Current path to sensor 2 0V Ground 0V Ground BR1 Not ass...

Страница 18: ...ement results The three wire mode is recommended for longer cables This solution corrects the resistance of the supply line UX I UX 3 0V 5 I 4 BR 6 0V 8 BR 7 SHLD 9 SHLD 10 2 1 UX I UX 3 0V 5 I 4 BR 6...

Страница 19: ...roller type Type of connection between controller and expansion module Position and amount of expansion modules in the system The amount of expansion modules which can be connected to a controller de...

Страница 20: ...ctly accessed via I O numbers These I O numbers consist of a five digit prefix the module position in the system and the I O number of the module The I O numbers always start with the constant prefix...

Страница 21: ...via I O numbers The I O numbers consist of prefix 1 the GNN prefix 2 the module position in the system and the module specific I O number Fig 14 Example I O numbers Digits Description Value range 1 Pr...

Страница 22: ...it coded 32 bits Value after reset 0x00210000 in faultless condition 0x40210000 Bit values Description Bit 0 Hardware error 0 No error 1 Hardware error The exact cause of the error can be determined b...

Страница 23: ...e user Bit 19 Lower limit Type Collective bit 0 No error 1 Value below lower limit At least one temperature input has fallen below the lower limit value The bit is set by the module it is reset by the...

Страница 24: ...ffi cient temperature 70 Resetting the lower limit value during min max value storage 71 Resetting the upper limit value during min max value storage 72 Resetting both limit values during min max valu...

Страница 25: ...eter Mode Returning to normal measuring mode 181 Enabling Potentiometer Mode If a value has been entered into module register 1y03 the reading is indicated in module register 0002 or 0003 as relative...

Страница 26: ...tively 0003 Bit 12 Calibration mode 0 Disabled 1 Enabled Bit 13 Potentiometer mode 0 Disabled 1 Enabled Bit 14 Channel enabled disabled 0 Disabled 1 Enabled Bit 15 Reset 0 No reset normal measuring mo...

Страница 27: ...a lower and upper limit Module register 1Y08 Description Lower limit Defining the lower limit The module checks with each conversion whether the value has fallen below the limit value Notation The val...

Страница 28: ...and 2 Module register 9741 Parameter index Description Parameter index of module register 9742 Type of access Read write Value range 0 30 Module register 9742 Description Parameter value The parameter...

Страница 29: ...dule register value for trigger condition 2 30 Size of the post buffer Value range 0 100 Module register 9743 Description Index of recorded values of module register 9744 Type of access Read write Mod...

Страница 30: ...ion 100500 100501 EDS data selection 100600 100614 EDS Page 0 Data 100700 100710 EDS Page 1 Data Register values Description 100500 Interface 1 Position of the expansion modules in the system 100501 M...

Страница 31: ...device and its functions are not allowed In the case of modifications to the device any liability is excluded The original parts are specifically designed for the device Parts and equipment from other...

Страница 32: ...or use the contact form on our homepage Technical hotline Jetter We automate your success You are also welcome to send an e mail to our technical hotline hotline jetter de Please supply the following...

Страница 33: ...se damage to the product Only use accessories recommended by Jetter AG 11 1 Spare parts Component Item no 10 pin connector spring cage technology 60869252 10 pin connector push in connection 60869254...

Страница 34: ...e DIN rail 14 Fig 6 Dismounting example 15 Fig 7 Dismounting the enclosure from the backplane module 16 Fig 8 Connection examples in two wire and in three wire mode 18 Fig 9 Connection examples in fou...

Страница 35: ...conditions 10 Tab 2 Electrical properties 11 Tab 3 Temperature inputs 11 Tab 4 Mechanical specifications 11 Tab 5 Electrical safety 12 Tab 6 Emitted interference 12 Tab 7 Immunity to interference 12...

Страница 36: ...60884091 We automate your success Jetter AG Graeterstrasse 2 71642 Ludwigsburg www jetter de E mail info jetter de Phone 49 7141 2550 0...

Отзывы: