7 Description of Connections
74
Jetter AG
7.8
Sin- / Cos-Encoder Connection
7.8.1
Specification
Specification of the Connector for Terminal X61 (ENCODER)
• 15-pin high density SUB-D connector (male)
• Metallized enclosure
Sin-Cos Encoder Cable Specifications
• Cable cross-sectional area of at least 3 * 2 * 0.14 mm² + 2 * 0.25 mm² min.
• 2 * 0.25 mm² must be used for the power supply unit and for GND
• Twisted-pair cables shielded with the all-over shield must be used; the signal lines
must also be twisted in pairs:
Sine + and reference sine
and reference cosine
Index + and reference index
0 V and voltage supply
• The shield must be connected to the connector housings on both ends of the
cable with the greatest possible surface area.
• Material: Copper
• Temperature class: 60 °C
• Maximum cable length: 50 m