7 Description of Connections
70
Jetter AG
LinMot Encoder Cable
JetMove 105
(male SUB-D connector
X61)
Shield
Cable specification
Maximum cable length:
25 m
Attaching screws must
have a metric thread!
Connect shield with the
greatest possible surface
area!
Use metallized housing
only!
Pin
Signal
Core Color
5
Sine
amber
4
Cosine
green
1
Voltage output
(5 volts)
white
11
0 V
inner shield
Shield
Shielding
outer shield
1
6
11
5
10
15
Shield
Note 1!
Supply v5 V at the JetMove 105:
Due to conduction loss, a lower voltage might be supplied to the encoder.
Note 2!
The LinMotor motor cable features double shielding. Do not connect both
shields with each other. The inner shield is used as 0 V line. Connect it to
0 V signals only! The outer shield must be connected to the shielding
terminal of the Sub-D connector.
Содержание JM-105
Страница 1: ...User Manual JM 105 Digital Servo Amplifier 60872838 We automate your success...
Страница 10: ...Table of Contents JetWeb 10 Jetter AG...
Страница 21: ...JetMove 105 2 2 Mechanical Installation Jetter AG 21 Fig 3 Recommended mounting m i n 2 5 m m...
Страница 26: ...2 Installing the JetMove 105 26 Jetter AG...
Страница 32: ...3 Operating Conditions 32 Jetter AG...
Страница 34: ...4 Physical Dimensions 34 Jetter AG...
Страница 40: ...5 Technical Specifications 40 Jetter AG...
Страница 84: ...7 Description of Connections 84 Jetter AG...
Страница 96: ...11 Ordering Information 96 Jetter AG...
Страница 97: ...JetMove 105 Appendices Jetter AG 97 Appendices...
Страница 98: ...Appendices 98 Jetter AG...