7 Description of Connections
JetWeb
58
Jetter AG
7.5
Digital Inputs, Logic Power Supply
Digital Inputs, Logic Power Supply
Wiring
terminal X10
at the
amplifier
Signal
Function
Specification
ENABLE
Hardware
enable for
the power
supply of the
motor
(Input)
• At this input, a high
signal is necessary for
power supply of the
motor. (This signal must
have been applied
before carrying out the
software enable)
• A low signal de-
energizes the motor
immediately.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low,
> 15 V high
REF
Reference
switch
(Input)
• Depending on the
parameter setting, this
input is used for
reference run
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low,
> 15 V high
NC or NO contact
LIMIT +
Positive limit
switch (input)
• Depending on the
parameter setting, this
input is used as a
positive limit switch.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low,
> 15 V high
NC or NO contact
LIMIT -
Negative
limit switch
(input)
• Depending on the
parameter setting, this
input is used as a
negative limit switch.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low,
> 15 V high
NC or NO contact
INPUT
Digital Input
• Depending on the
parameter setting, this
input can be used for
quick stop, position
capture or referencing
without stop.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low,
> 15 V high
Содержание JetWeb JetMove 203-230
Страница 34: ...4 Physical Dimensions JetWeb 34 Jetter AG...
Страница 42: ...5 Technical Data JetWeb 42 Jetter AG...
Страница 62: ...7 Description of Connections JetWeb 62 Jetter AG...
Страница 70: ...9 Diagnostics JetWeb 70 Jetter AG...
Страница 76: ...10 Wiring Diagrams JetWeb 76 Jetter AG...
Страница 79: ...JetMove 203 230 Appendix Jetter AG 79 Appendices...
Страница 80: ...Appendices JetWeb 80 Jetter AG...
Страница 89: ...JetMove 203 230 Appendix Jetter AG 89...