1.4 Instructions on EMI
Jetter AG
19
Fig.2: Shielding of SUB-D connectors in conformity with EMC standards.
Shielded cables
must
be used for the following lines:
Analog lines, data lines, motor cables coming from inverter drives (servo
output stage, frequency converter), lines between components and
interference suppressor filter, if the suppressor filter has not been placed
at the component directly .
Shield
both sides
of the cable.
Unshielded wire ends of shielded cables should be as short as possible.
The
entire
shield must be drawn behind the isolation, and then be
extensively
clamped under a flat earthed strain relief.
If male connectors are used:
The shield (impedance shielding)
must
, in its entire perimeter, be drawn
behind the shielding clamp of the metallised connector housing,
respectively of the EMC gland bushing, its greatest possible surface area
being clamped under a strain relief.
Only use metallised connectors, e.g. SUB-D with metallised housing.
Make sure that the strain relief is directly connected with the housing here
as well (see Fig. 2).
What to do, if the shield cannot be fixed to the connector, e.g. if the signal
has been connected to terminal screws:
Shield and cable strap must be connected with low impedance to earthed
surfaces. Earthing must be done in a way that keeps the unshielded part of
the signal lines as short as possible (see Fig. 3).
Содержание JetWeb JetMove 203-230
Страница 34: ...4 Physical Dimensions JetWeb 34 Jetter AG...
Страница 42: ...5 Technical Data JetWeb 42 Jetter AG...
Страница 62: ...7 Description of Connections JetWeb 62 Jetter AG...
Страница 70: ...9 Diagnostics JetWeb 70 Jetter AG...
Страница 76: ...10 Wiring Diagrams JetWeb 76 Jetter AG...
Страница 79: ...JetMove 203 230 Appendix Jetter AG 79 Appendices...
Страница 80: ...Appendices JetWeb 80 Jetter AG...
Страница 89: ...JetMove 203 230 Appendix Jetter AG 89...