40K Hose Connections
1. Remove the supply hose (Figure 41) (supply
from charge pump) from the suction elbow
fitting on the 15K/20K manifold.
2. Install the 40K manifold as outlined earlier in
this chapter.
3.
Remove the plug from the filter outlet hose
(Figure 42). Connect the hose to the elbow on
the 40K manifold.
4.
Remove the cap from the secondary filter inlet
coupling (Figure 43).
5. Install the charge pump supply hose on the
secondary filter inlet coupling.
!
CAUTION
When flushing the system before operation,
purge the secondary filter of air. Failure to do so
could cause pump cavitation and damage. Use
the bleed valve (Figure 43) on the filter to purge
the air from the filter.
Bleed Valve
Figure 43:
Secondary Filter Bleed Valve.
Figure 41:
Supply Hose from Charge Pump.
Elbow
Supply from
Charge Pump
Figure 42:
Plumbing.
Elbow
Filter Outlet
Hose
Supply from
Charge Pump
Secondary
Filter
Filter Inlet