Jets VFD Valve Скачать руководство пользователя страница 7

VFD Valve, Piston Complete

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. 054100973

Doc. Rev.: 8 (2022-03-04)

7

The toilet bowl slowly fills up with 
water.

The water valve is leaking.

Replace the sealing flap.

Flushing and discharge does not stop.

The valve in the release button does 
not close.

Replace the release button.

The signal hose between the release 
button and the VPC-V Controller is 
leaking.

Check the signal hose and connections for air leakages. 
Replace if required.

The normal water level in the toilet 
bowl is reducing or low.

Low pressure on the water supply.

Increase pressure on the water supply.

Impurities prevent the shut-off 
membrane from closing.

Lower housing to be cleaned.

Dirt in the water supply filter.

Clean or replace the filter.

Shut-off membrane is damaged.

Replace the shut-off membrane.

Flushing and discharge cycles are 
incorrect.

The air orifice is dirty.

Clean the orifice.

Содержание VFD Valve

Страница 1: ...r products and services are offered and sold subject to Jets Vacuum AS General Sales Conditions copies of which will be furnished upon request Information provided herein is solely for information purposes does not constitute any warranty or representation of any kind and is subject to change without notice We strive to reproduce product colors reasonably accurate Without prior written approval th...

Страница 2: ...VFD Valve Piston Complete Tel 47 70 03 91 00 www jetsgroup com Product No 054100973 Doc Rev 8 2022 03 04 2 Dimension Drawings A 235mm B 195mm C 290mm D 50mm E Ø60 ...

Страница 3: ...the Source C Outlet from the Source D Air Inlet E D Valve Outlet Vacuum in the piping as indicated Normal Position Closed Valve VPC V Controller ℯ CLOSED D Valve Ⅎ CLOSED Emptying Sequence 1 Release Mechanism ℰ OPEN 2 VPC V Controller ℯ OPEN 3 D Valve Ⅎ OPEN Closing Sequence 1 Release Mechanism ℰ CLOSED 2 Air is sucked into the VPC Controller ℯ deciding the controller s timing 3 VPC V Controller ℯ...

Страница 4: ...nce with the instructions provided Do not exceed the limits provided 2 2 Warning The client is responsible for installation service and maintenance by a qualified person 2 9 Warning Do not disassemble repair or modify the product without contacting a qualified tradesman 12 5 Notice Use this equipment only in the manner intended by Jets Vacuum AS If you have questions after reading these instructio...

Страница 5: ...val of the valve Service and Maintenance Disassembly Instructions 1 Turn off the water supply to the valve Release any liquid in the water source i e toilet urinal etc 2 Pull the release mechanism hose from the controller 3 Remove the hose clip and pull to remove the flushing device 4 If a transport spring is installed release the spring connecting the lower housing of the valve to the bowl and re...

Страница 6: ...nterval Action Note Maintenance depends on flushes per year This will vary depending on the segment i e ship cabin train public etc Inspect the discharge valve Clean and change any worn parts if necessary The shut off membrane is normally the first item that needs to be replaced The piston valve has been tested and has reached 200 000 flushes without any need of maintenance Troubleshooting Jets Va...

Страница 7: ...elease button and the VPC V Controller is leaking Check the signal hose and connections for air leakages Replace if required The normal water level in the toilet bowl is reducing or low Low pressure on the water supply Increase pressure on the water supply Impurities prevent the shut off membrane from closing Lower housing to be cleaned Dirt in the water supply filter Clean or replace the filter S...