background image

Installation instructions Jetmaster Mark 2 Gas Coal / Pebble

Commissioning Procedure

Installed correctly the burner should not emit any
fumes into the room. The following procedure should
be undertaken to test that the unit is operating
correctly.

1. After unit has been operating for a short period a
smoke match, smoke tube, carbon dioxide analyser or
similar should be directed at the top opening of the
unit.

2. This procedure should be undertaken with the
following conditions in the room:

• Open or closed windows
• Operation of extraction/exhaust fans, range 
hoods etc
• Operation of other gas appliances
• Operation of optional appliance fan at any speed.

3. Should any spillage be detected the cause must be
rectified before allowing commissioning of unit.

User Instructions

1. WARNING NOTE: Properly installed and operated
this appliance will not leak gases. Persistent fume
emission must not be tolerated. If fume emission does
exist, then the following immediate action should be
taken.

A. Open doors and windows to ventilate room.

B. Turn the fire off.

C. Check for flue blockage and clear if necessary.

D. Do not attempt to relight the burner until the cause
of the emission has been identified and rectified. Should
assistance or advice be required contact nearest agent
or Jetmaster.

E. The gas grate is recommended for use in a
Jetmaster firebox which has been designed to ensure a
proper draw and to eliminate emission spillage.

2. Initially the Jetmaster coal / pebble fire may burn with
a slightly blue flame.After approximately 20 minutes the
fire will settle down and burn with a yellow flame.

3. As with all gas appliances your gas coal / pebble fire
should be regularly serviced. We recommend once
each year. Contact your nearest Jetmaster authorised
agent to provide service.The routine for an authorised
person to follow has been set out in an attached leaflet.

4. PLEASE NOTE: Only coals / pebbles provided by
Jetmaster should be used with this appliance.

5. DO NOT place articles on or against this appliance.

DO NOT use or store flammable materials near 
this appliance.

DO NOT spray aerosols in the vicinity of this 
appliance whilst it is in operation.

Primarily a decorative appliance not certified as a 
space heater.

6. The appliance is a live fuel effect product designed
to operate with luminous flames and may exhibit slight
carbon deposition.

Warranty

Provided the appliance has been correctly installed
according to instructions, Jetmaster guarantee the
cost of replacing parts and the labour in connection
therewith for a period of 12 months from the date of
installation. Should the appliance be subject to a
service contract the replacement of the parts and
the service involved in such replacement shall be at
no charge to the owner and the Warranty shall be
extended to 3 years (provided of course the
appliance had been continuously serviced by an
approved Jetmaster agent).

Содержание Mark 2 Gas Coal

Страница 1: ...Installation instructions Jetmaster Mark 2 Gas Coal Pebble with Millivolt Control...

Страница 2: ...imney should be tested and proven to have an adequate updraft which shall be sufficient to remove all waste products of combustion A minimum cross sectional area of 40 000 sq mm is required with a min...

Страница 3: ...ol knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly de...

Страница 4: ...HOW TO ADJUST GAS PRESSURE...

Страница 5: ...of coals in a honeycomb pattern to form an elongated pyramid Lay the coals pebbles so that some irregularity to the pile through which the flames may lick is created Your aim is to build windows into...

Страница 6: ...which has been designed to ensure a proper draw and to eliminate emission spillage 2 Initially the Jetmaster coal pebble fire may burn with a slightly blue flame After approximately 20 minutes the fir...

Страница 7: ...existing masonry fireplace or equivalent approved open fireplace The gas fire consists of an outer decorative grate which houses a mild steel burner tray A front plate is provided to cover controls CA...

Страница 8: ...s welded onto a 4 5mm guage mild steel frame to provide the appearance of a solid fuel basket grate A 1 6mm guage folded mild steel tray is located within the basket grate It is welded to the back of...

Страница 9: ...located under the burner tray Burner A folded mild steel tray with deflector plate A cast iron venturi tapered mixing tube is welded to the base through which gas is introduced Pilot S I T Pilot asse...

Страница 10: ...For LPG the appliance regulator requires removal Note pressures on data plate for natural and LP gas and adjust accordingly The test point is located on the SIT valve HEATING SYSTEM Vermiculite Is var...

Страница 11: ...the safety magnet Millivolt systems utilise power from the thermo generator 7 After the pilot has been lit for approximately three minutes and only the thermo generator wires connected to the main ope...

Страница 12: ...ure with main burner running see diagram Pilot adjustment screw not properly adjusted Refer to item 7 in the set up guide also see diagram Thermocouple or thermo generator not properly inserted into t...

Страница 13: ...and TP If the voltage is above 110mV and the safety magnet does not hold replace the valve Pilot injector blocked Replace injector with a new injector of the exact size and type Pilot drops out Wrong...

Страница 14: ...at wiring except substitute the words wall switch where the word thermostat appears in the instructions Excessive wire resistance Make certain that all mV connections are made using wire of the proper...

Страница 15: ...Notes For further information contact Jetmaster Australia 10 Martin Avenue Arncliffe NSW 2205 T 02 9597 7222 F 02 9597 7622 E sales jetmaster com au W www jetmaster com au...

Отзывы: