Jetmaster Mark 2 Gas Coal Скачать руководство пользователя страница 3

Installation:
Fitting the Gas Grate

1. Check unit is suitable for intended gas supply.

2. The position of the gas control and inlet is on the right hand
side and is 3/8" B.S.P. female connection for L.P.G. A 1/2" regulator
is  supplied  when  fitting  to  natural  gas. Check  that  the  chimney  is
clear prior to fitting.

3. In an existing fireplace or Jetmaster firebox (if being used) drill
a  15mm  hole  through  the  right  hand  side  of  the  fireplace(as  you
face it) at a point of 85mm from the base and 85mm from the rear
wall(if providing stop cock in firebox).85mm from front wall (if stop
cock is outside firebox).

4. Cut and debur both ends of pipe. Fit the end to the gas supply
point and turn on for approximately 5 seconds to clear the pipe of
any dirt or grit. Fit the other end to the gas unit.

5. The regulator is included on the S.I.T. control on the unit.

6. Turn on the gas and check all connections for leaks using soapy
water or approved method. Fix any leaks.

7. Possible  carbon  deposition  may  occur  on  the  appliance
incorporating live fuel effect.

Adjusting Pressure, Pilot 
and Low Fire

1. All settings are set to operate at appropriate pressures (see data
plate)

.

Test point is located on gas valve.

2. Check low fire if adjusted correctly.

3. The  pressure  can  be  measured  on  the  gas  valve  and  the
regulator  adjusted  to  the  appropriate  pressure  (see  data  plate
affixed to side of the appliance.)

Lighting Instructions

PILOT FLAME IGNITION 

Locate control knob on right hand side of valve. Depress and turn
control knob 

(FIG 1) 

to the    

PILOT position 

(FIG 4).

Depress

the  control  button  and  ignite  with  piezo  ignitor 

(FIG  2) 

whilst

keeping control knob firmly depressed for 20 seconds. Check that
pilot stays lit. If it goes out repeat ignition procedure.

MAIN BURNER IGNITION

Depress  and  turn  control  knob  anti-clockwise  from       

PILOT 

position  to  the        ON  position 

(FIG  5).

The  burner  will  not 

ignite if the rocker switch is depressed in the OFF position 

(FIG 3).

To light main burner press rocker switch to ON position 

(FIG 3).

TO TURN MAIN BURNER OFF WITH PILOT 
REMAINING BURNING

Depress rocker switch to OFF position.

(FIG 3)

Main burner can also be turned off by the use of control knob.This
is done by turning control knob clockwise to    

PILOT position

(FIG  8).

Control  knob  will  need  to  be  turned  back  to       

ON

position 

(FIG 5) 

to light main burner.

TO TURN MAIN BURNER OFF OR ON WITH 
OPTIONAL WALL SWITCH

Pilot must be burning.
Control knob is in the         ON position.

(FIG 5)

Rocker switch is in the OFF position.

(FIG 3)

Wall switch can now be activated.

Important! Wall switch can only be activated if rocker switch is in
off position.

TO TURN PILOT AND MAIN BURNER OFF

Depress and turn control knob clockwise from 

ON position 

(FIG  5) 

or          PILOT position  (FIG  4)  to  the

OFF  position 

(FIG 6).

TO TURN MAIN BURNER HIGHER OR LOWER

Turn high / low flame knob to obtain high or low fire 

(FIG 7)

.

Installation Instructions Jetmaster Mark 2 Gas Coal/Pebble

Fig 1

Control knob

Fig 2

Pietzo Igniter

Fig 3

Rocker Switch

Fig 6

clockwise  

Fig 5

ant

i clockwise  

Fig 4

ant

i clockwise  

Low flame

High flame

High / Low
flame knob

Fig 7

Fig 8

clockwise  

Содержание Mark 2 Gas Coal

Страница 1: ...Installation instructions Jetmaster Mark 2 Gas Coal Pebble with Millivolt Control...

Страница 2: ...imney should be tested and proven to have an adequate updraft which shall be sufficient to remove all waste products of combustion A minimum cross sectional area of 40 000 sq mm is required with a min...

Страница 3: ...ol knob on right hand side of valve Depress and turn control knob FIG 1 to the PILOT position FIG 4 Depress the control button and ignite with piezo ignitor FIG 2 whilst keeping control knob firmly de...

Страница 4: ...HOW TO ADJUST GAS PRESSURE...

Страница 5: ...of coals in a honeycomb pattern to form an elongated pyramid Lay the coals pebbles so that some irregularity to the pile through which the flames may lick is created Your aim is to build windows into...

Страница 6: ...which has been designed to ensure a proper draw and to eliminate emission spillage 2 Initially the Jetmaster coal pebble fire may burn with a slightly blue flame After approximately 20 minutes the fir...

Страница 7: ...existing masonry fireplace or equivalent approved open fireplace The gas fire consists of an outer decorative grate which houses a mild steel burner tray A front plate is provided to cover controls CA...

Страница 8: ...s welded onto a 4 5mm guage mild steel frame to provide the appearance of a solid fuel basket grate A 1 6mm guage folded mild steel tray is located within the basket grate It is welded to the back of...

Страница 9: ...located under the burner tray Burner A folded mild steel tray with deflector plate A cast iron venturi tapered mixing tube is welded to the base through which gas is introduced Pilot S I T Pilot asse...

Страница 10: ...For LPG the appliance regulator requires removal Note pressures on data plate for natural and LP gas and adjust accordingly The test point is located on the SIT valve HEATING SYSTEM Vermiculite Is var...

Страница 11: ...the safety magnet Millivolt systems utilise power from the thermo generator 7 After the pilot has been lit for approximately three minutes and only the thermo generator wires connected to the main ope...

Страница 12: ...ure with main burner running see diagram Pilot adjustment screw not properly adjusted Refer to item 7 in the set up guide also see diagram Thermocouple or thermo generator not properly inserted into t...

Страница 13: ...and TP If the voltage is above 110mV and the safety magnet does not hold replace the valve Pilot injector blocked Replace injector with a new injector of the exact size and type Pilot drops out Wrong...

Страница 14: ...at wiring except substitute the words wall switch where the word thermostat appears in the instructions Excessive wire resistance Make certain that all mV connections are made using wire of the proper...

Страница 15: ...Notes For further information contact Jetmaster Australia 10 Martin Avenue Arncliffe NSW 2205 T 02 9597 7222 F 02 9597 7622 E sales jetmaster com au W www jetmaster com au...

Отзывы: