background image

d)  Installations that are subjected to prolonged periods of dampness or condensation.
e)  Any damage to the combustion chamber, heat exchanger or other components due to water or weather 

damage which is the result of but not limited to, improper chimney/venting installation.

f)  Parts fitted to the appliance other than supplied by Jetmaster.

9.  This Guarantee is limited to the repair or replacement of parts found to be defective in material or workmanship 

after  confirmation  of  the  defect  by  Jetmaster,  provided  that  such  parts  have  been  subjected  to  normal 

conditions of operation.

10. Jetmasters liability shall be limited to the cost of the unexpired portion of the Guarantee period.
11. This Guarantee is valid from the date of the original purchase.

12. All other Guarantees expressed or implied with respect to the product, it’s components and accessories or 

any obligations/liabilities on the part of Jetmaster are hereby expressly excluded.

13. Jetmaster will not be responsible for any incident, indirect or consequential damages, except as provided by 

law.

14. Jetmaster neither assumes, nor authorises any third party to assume, on it’s behalf, any other liabilities with 

respect to the sale of this “Jetmaster” fire.

The Guarantees Do Not Cover:-

Any alteration, wilful abuse, accidental damage or misuse of the product.

Routine maintenance/Service.

Parts that need to be replaced on a routine basis e.g. Bottom grates, V boards, etc. and cosmetic blemishes to 
polished metal surfaces after one year.

Once satisfied that the above conditions have been complied with and provided that evidence of the date of 
purchase from an appointed distributor within five years can be produced by the then owner of the product and 
the defect is notified in writing to the appointed Distributor and Jetmaster within five years of the purchase date 

of the product, then, Jetmaster at its discretion, will arrange with the appointed Distributor either to replace or 
repair the faulty product.

Statutory Rights

These guarantees are additional to and do not in any way affect the statutory rights of the buyer.

Complaints

When making a complaint under either of the above Guarantees, the owner 

should not contact Jetmaster

 

direct unless he is unable to contact the Appointed Distributor.

Specifications

Whilst  every  endeavour  is  made  to  supply  the  goods  illustrated  in  Jetmasters  brochures,  any  photographs, 

descriptions, specifications, illustrations or advertising matter represent generally Jetmasters goods offered, but 

shall not constitute a sale by description.

Jetmaster reserves the right to supply similar but not identical goods to those illustrated provided that the overall 
construction and design has not been altered fundamentally. Further, any deviation shall not be taken to vitiate 
any contract and shall not form the grounds for any claim against Jetmaster.

Trademark

“Jetmaster” is the United Kingdom Registered Trademark of Jetmaster Fires Limited No B809215

Jetmasters policy is one of continual advance in the quality of our products. Thus strict accuracy of illustrations 

and descriptions cannot be guaranteed. We reserve the right to change this specification without notice. Whilst 

we and our distributors will endeavour to ensure that you have the most up-to-date information, we urge you to 
check the date at the end of this publication, and, if it is more than six months old, to check with your Distributor 
to ensure it has not been superseded. The statutory rights of the consumer are not affected.

34

Содержание INSET STOVE MKIII 60i

Страница 1: ...on Operating and Servicing Instructions Please leave these instructions with the customer SERIAL NUMBER JETMASTER MK6 GAS JETBOX RANGE Installation and Operating Instructions For Manual Control Comfor...

Страница 2: ...ting the Fire 13 Site Preparation for Fitting 13 Builders Opening 13 Inglenook Installations or Freestanding 13 Appliance Preparation 13 Door Removal 13 Tertiary Air Tube Removal and V Board Baffle Re...

Страница 3: ...ass Door 28 Servicing Instructions Servicing 29 Chimney Sweeping 29 Seal Checks 29 Smoke Draw Test 29 Door Removal and Refitting 29 Log Retainer Removal 29 Tertiary Air Tube Removal and V Board Baffle...

Страница 4: ...ate Installation By Installer Name Company Address Tel Commissioning Flue type correct Flue swept and soundness checked Smoke draw test spillage carried out Air supply checked Controls explained HETAS...

Страница 5: ...meter MAXIMUM REFUEL WEIGHT MINIMUM REFUEL INTERVAL A mm ins B mm ins C mm ins D mm ins E mm ins F mm ins mm ins mm ins mm ins Kg M kW C gs 1 mm in cm2 in2 Pa M ft cm in mm Kg Min 18i 488 19 1 4 571 2...

Страница 6: ...of the Environment or the Building Standards Scotland Consolidation Regulations issued by the Scottish Development Department l All relevant codes of practice and relevant parts of any local regulatio...

Страница 7: ...good seal with the outer firebox can be made and to enable the finishing frame to fit Any excessive unevenness uneven tiles stone etc should be rectified The front face of the fireplace should be rea...

Страница 8: ...t be used for any other appliance or application Use of Existing Chimneys These must be swept and inspected for dimensions and soundness before starting to install the fire Existing flue liners should...

Страница 9: ...a structural unit although very robust it is not designed to take the weight of the flue Therefore a structural lintel will need to be provided for clay liners or in the case of pre fabricated stainl...

Страница 10: ...s recesses and chimneys should be constructed to conform to Building Regulations Document J Hearths or plinths constructed to support the fire above the hearth must be horizontal Any hole in the wall...

Страница 11: ...The size of air supply duct or ducts recommended for each fire is shown in the installation data table page 5 The Building Regulations Document J and L must be taken into account when providing ventil...

Страница 12: ...a manner which achieves conditions as close as possible to the above perhaps by use of ducting or false skirting When bringing in the air supply consideration should be given to any regulations that w...

Страница 13: ...ions or freestanding The fire should be set within a brick stone or non combustible recess built within the inglenook The flue connection from the top of the fire to the chimney can be made with flue...

Страница 14: ...the tube hole the bolt is tightened to hold it in this position thus trapping the tube This ensures that the tube will not slide out and it keeps the tube with its tertiary air ports in the correct p...

Страница 15: ...orts are in their correct position within the fire Ensure that the V board baffles are fitted the correct way around Rear tertiary air tube Front and back tertiary tubes are designed to slide across t...

Страница 16: ...CLAMP Internal V Board Removal Bottom Rear and Sides The internal V boards need to be taken out in the following sequence IMPORTANT First remove Cast Bottom Grate then Bottom V boards then Rear V boar...

Страница 17: ...on the guides from the outer box The engine contains easy grip areas that allow 2 people to easily lift it out With the inner and outer boxes now separate work can begin to fit the outer firebox into...

Страница 18: ...rebox as expansion of the fire may cause them to crack Use a strip of insulation as an expansion joint where necessary Note If an external primary air supply is to be used then the knockout in the rea...

Страница 19: ...fixings to hold it in place Take care not to damage the adaptor seal at any stage A tight and effective seal must be made between the firebox and flue It is essential that the system be sealed at eac...

Страница 20: ...low Fitting the Basket Grate Optional Extra The basket can be slide into the firebox centrally It should be pushed back to the rear of the firebox and then pulled foreword slightly by a few millimetre...

Страница 21: ...n the inner box push towards the inner box and then push down locating the hooks on the frame over the firebox tags If the frame cannot be engaged then adjust the inner firebox either by pulling outwa...

Страница 22: ...the opening of the fire and ignite the pellet Open the air control valve and close the door Check that the smoke is being drawn up the flue and that it is discharging satisfactory at the flue termina...

Страница 23: ...bes and V board baffles to facilitate chimney sweeping and for the removal of soot from the unit See Servicing Instructions Handing Over l Read the Users instructions and instruct the user on the oper...

Страница 24: ...it is the law that all solid fuel appliances are installed by competent persons a registered installer or approved by your local building control officer The Heating Equipment Testing and Approval Sc...

Страница 25: ...d Please bear this in mind when installing or decorating DO NOT operate the fire with a cracked glass DO NOT obstruct the hot air outlets by hanging clothing etc over the hood DO NOT touch the externa...

Страница 26: ...the variability of the heat produced from a solid fuel fire It is dependent on the quantity of fuel used and the refuelling frequency Hot air can cause staining above the fire in the same manner as a...

Страница 27: ...al The removable ash pan simply slides out from under the cast grate for easy emptying Do not allow ash to build up under the basket grate bars If they are allowed to become covered they will overheat...

Страница 28: ...of green firewood means you may have been buying as much water as you are wood When wood is burned the water content is converted into steam The large amount of heat necessary to do this accounts for...

Страница 29: ...t has fallen on to the top of the V board baffles is removed Ensure that any soot that has accumulated around the tertiary air tube holes is removed Remove and clean the tertiary air tubes and the V b...

Страница 30: ...nd check condition If any boards show signs of surface damage or are broken then they should be replaced Replacement parts are available from your Jetmaster Distributor For replacement of tertiary air...

Страница 31: ...hen slide the boards towards the centre of the fire To replace the V boards offer one edge in first and then push the V board gently back Note They should be pushed back flat against the steel body of...

Страница 32: ...e hole in the glass around the door catch does not touch the latch at any point There should be a small gap all around the latch to the glass This will allow the metal to expand when heated to avoid c...

Страница 33: ...this Guarantee The Guarantee does not cover rust or paint Terms and Conditions This guarantee is only effective if the Guarantee Registration Card has been fully completed at Jetmasters offices withi...

Страница 34: ...ve years can be produced by the then owner of the product and the defect is notified in writing to the appointed Distributor and Jetmaster within five years of the purchase date of the product then Je...

Страница 35: ...35...

Страница 36: ...tails Jetmaster Fires Ltd Peacock Trading Estate Goodwood Road Eastleigh Hampshire SO50 4NT Telephone 02380 629513 Fax 02380 629567 Email jetmastersales aol com Web www jetmaster co uk Issue No 1 Febr...

Отзывы: