A.  Preparation for Welding

Mount the spool of welding wire on the spool 

adapter so the wire will be pulled from the low 

side of the coil.  Adjust the friction brake on the 

wire spool by adjusting the screw in the center 

of the spool. If adjusted properly, the spool will 

feed smoothly and will not coast or continue to 

spin when feeding stops.
Debur the end of the wire, then insert it into the 

inlet guide through the feed rolls and the outlet 

guide. (Refer to Figure 3).
Press the power switch to the “On” position 

and feed the wire into the conduit by press-

ing “Forward” key. Continue to feed the wire 

through the conduit and the wire guide tip until 

a desired amount extends beyond the tip.
See the Quick Start Guide for various jog 

modes.

B. Operation

9629 Control:

The operation of a CWF-50 is not difficult. The 

following sequence is suggested:
1. 

 Turn on power to unit.

2. 

 Using the Forward key, inch the wire 

forward a little.  Trim the wire if there is 

a ball on the end of the wire.  This step is 

especially necessary if feeding wire and 

using an arc length control.  A ball on the 

end of the wire could touch the tungsten 

when feeding initially. If the wire con-

tacts the tungsten, you will get a “ball” 

on the end of the tungsten. The operator 

should stop the weld and resharpen the 

tungsten. This action could also cause 

adverse effects with the arc length con-

trol.

 

 When the wire is inched forward, this is 

a good time to verify the wire’s position.  

Adjust if necessary.

3. 

 Retract wire to desired starting position 

using the Reverse key.

4. 

 Check wire and wire spool briefly. Veri

-

fy there is enough wire for the next weld 

and that the wire is not wrapped around 

the spool holder.

5. 

 Check wire feed speed setting, the start 

delay setting, and the stop retract setting. 

These settings are critical to achieve the 

desired weld.

6. 

 At this point, the unit is ready to feed 

wire.  If the starting and stopping of the 

wire is controlled remotely, the control 

will go through the start delay.  Once 

this delay has timed out, the unit will 

proceed to feed wire at the rate set on 

the dial.

 

 When the remote start signal quits, the 

unit will go through the stop delay, then 

stop.  The unit then proceeds to enter the 

wire retract time, pulling the wire out of 

the weld zone.  This action prevents the 

wire from sticking in the weld puddle at 

the end of the weld.

 

 Note: If the retract time is set too long, 

the wire could retract up into the wire 

tip. If this happens, the wire could, on 

occasion, get stuck on the tip on the next 

weld.

Содержание CWF-50

Страница 1: ...49 951 9237 Web Site www jetline com E mail sales jetline com Revised January 2014 Effective with Serial Number 070159 IMPORTANT Read this manual carefully before installing commissioning or operating...

Страница 2: ...Model CWF 50 Cold Wire Feeder ii...

Страница 3: ...during the warranty period if Jetline s inspection confirms the existence of such defects Jetline s option of repair or replacement will be F O B factory at Irvine California and therefore no compens...

Страница 4: ...you to maintain the equipment in peak condition and achieve maximum efficiency with your welding opera tion Please read these instructions carefully to become aware of every advantage CAUTION Only ex...

Страница 5: ...tandards 4 Section II 5 General Description 5 Section III 7 Installation 7 Section IV 11 Operating Instructions 11 A Preparation for Welding 11 B Operation 11 C Wire Guide Positioner 12 Section V 15 W...

Страница 6: ...Model CWF 50 Cold Wire Feeder vi Section VIII 21 Parts Lists 21...

Страница 7: ...mproperly grounded equipment is a hazard 1 Do not touch live electrical parts 2 Wear dry hole free insulating gloves and appropriate body protection 3 Disconnect input power before installing or servi...

Страница 8: ...an approved air supplied respirator 4 Read the Material Safety Data Sheets MSDS and the manufacturer s instruc tion for metals consumables coatings cleaners and degreasers 5 Work in a confined space o...

Страница 9: ...cover them with approved covers 4 Be alert that welding sparks and hot mate rials from welding can easily go through small cracks and openings to adjacent areas 5 Watch for fire and keep a fire extin...

Страница 10: ...pacemaker wearers Consult your doctor for complete information I Principal Safety Standards Reference as applicable Safety in Welding and Cutting ANSI Standard Z49 1 from American Welding Society 550...

Страница 11: ...1 1 Wire drive unit consists of motor drive housing and wire spool assembly to feed wire Part number CWF 50 DA 2 9629 Control includes a keypad display encoder control knob start stop and emergency st...

Страница 12: ...WF 50 DA COLD WIRE FEEDER 6 CABLE 1 8M CONDUIT STANDARD LENGTH 6 FT 1 8M WGP 1 WIRE GUIDE POSITIONER 6 POWER CORD 1 8M Series 9600 CONTROL DOWN UP ADJUST REV FOR e g n i r e e n i g n e n i l t e E ST...

Страница 13: ...the wire feed kit is very critical to the successful operation of the cold wire feed unit Proper instal lation helps avoid bird nesting at the feed rolls and smooth wire feed delivery into the weld pu...

Страница 14: ...on duit into the wire guide tip Tighten the set screw holding the conduit securely into position Note On a rare occasion you may have to pull this end of the conduit from the tip when initially feedin...

Страница 15: ...CWF 50 Cold Wire Feeder 9 Figure 2 Mounting Plate Dimensions...

Страница 16: ...CWF 50 Cold Wire Feeder 10...

Страница 17: ...hen feeding initially If the wire con tacts the tungsten you will get a ball on the end of the tungsten The operator should stop the weld and resharpen the tungsten This action could also cause advers...

Страница 18: ...dle 1 Lateral adjustment of 1 4 1 8 adjust ment of tip on each side of weld seam 6 4 mm total adjustment 3 2 mm on each side 2 Vertical adjustment of 1 4 6 4 mm tip to work 3 Coarse adjustment of guid...

Страница 19: ...CWF 50 Cold Wire Feeder 13 Figure 3 Wire Feed Accessory Kit Components...

Страница 20: ...CWF 50 Cold Wire Feeder 14...

Страница 21: ...35 45 056192 WFT 030 046780 CWGT 030 0 035 0 9 1 mm 20B6035K 44N3545 OG 035 45 056192 WGT 035 046781 CWGT 035 0 045 1 2 mm 20B6045K 44N3545 OG 035 45 056193 WGT 045 046782 CWGT 045 0 062 1 6 mm 20B606...

Страница 22: ...CWF 50 Cold Wire Feeder 16...

Страница 23: ...lue 3 amp fast blow Periodically check and replace if necessary the carbon brushes on the motor Failure to re place worn brushes could cause severe damage to motor control Maintenance and electrical w...

Страница 24: ...CWF 50 Cold Wire Feeder 18...

Страница 25: ...on as it enters the weld puddle Due to the cast and helix in some wires the need to adjust the wire s position can be required JetlineofferstheWGP 2ESmotorizedpositioner so the operator can adjust the...

Страница 26: ...CWF 50 Cold Wire Feeder 20...

Страница 27: ...bly Two columns are included in the list to show the spare parts which are recommended to be stocked by the user The two levels can be de fined as follows Level 1 These are the spares recommended for...

Страница 28: ...CWF 50 Cold Wire Feeder 22...

Страница 29: ...r See chart in Section V 1 9 WGT 0__ Wire Guide Tip 1 See chart in Section V for complete part number 10 CWF 10 WG 60 Gear Reducer 1 11 95611AO31 Insulating Washer 1 12 8527K134 Insulating Tube 36 914...

Страница 30: ...CWF 50 Cold Wire Feeder 24 4 14 08 WGP 1 WIRE GUIDE POSITIONER L...

Страница 31: ...L 1 SB Swing Bolt 1 16 WGP 1 16 Lift Pin 1 17 6655K13 Thrust Bearing 1 18 VV 38 Compression Spring 1 1 19 1 4 20x7 8 Socket Head Screw 2 20 1 4 20x5 8 Socket Head Screw 2 2 2 21 1 4 Flat Washer 1 22 1...

Страница 32: ...CWF 50 Cold Wire Feeder 26 4 10 08 WGP 2ES COLD WIRE GUIDE POSITIONER SPECIAL MOTORIZED VERSION E...

Страница 33: ...5 REV C Motor Bracket detail 1 6 WGP 2 6 Screw 1 7 WGP 2 7 Motor Bracket detail 1 8 WGP 2 10 Driven Pulley detail 1 9 1375K34 Driven Pulley detail 2 10 WGP 2 10 Driven Pulley 1 11 1679K86 Belt 2 1 1...

Страница 34: ...CWF 50 Cold Wire Feeder 28 4 10 08 WGP 3 COMPACT WIRE GUIDE POSITIONER FOR COLD WIRE FEEDERS D...

Страница 35: ...Detail 1 9 WGP 3 9 Clamp Detail 1 10 WGP 3 10 Tube Detail 1 11 WGP 3 11 Spacer Detail 1 12 Fender Washer 1 13 XX 68 Compresion Pin 1 1 14 L 35 Compresion Pin 1 1 15 2813 Compresion Pin 1 16 CL 1 KHS...

Отзывы: