![JETI model MAX BEC Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/jeti-model/max-bec/max-bec_user-manual_3829503018.webp)
EN
MAX BEC / SBEC
MAX BEC / SBEC
3.2.5 Heat protection
The switching voltage regulator SBEC 30D contains a heat
protection means which prohibits destruction of the regulator by
long time effects of excessive current or by a short circuit. This
phenomena may, for instance, arise if a servo is short circuited or by
an excessive output load. If the heat protection is activated, the
regulator
„switches off“
for a short time necessary to cool down.
After cooling down the
SBEC 30D
switches automatically on again.
3.2.6 Setup
The condition of correct voltage is sufficient supply. The input
supply voltage from the batteries must always be higher than the
desired output voltage. We recommend that the power supply is at
least of 2V higher. Otherwise, the output voltage may decline
during the load. The switch on state of the regulator is signaled by
the green LED.
Notice:
1.
Always make sure that all the connected devices, such as
receivers, sensors and especially servos have the range of
permitted input voltage in the value of input voltage set by you.
2.
Always adjust the output voltage when the devices are
disconnected.
18 EN
magnetic or RC switch to activate the unit. To switch-off, always
use the magnetic or RC switch to turn-off the unit before
disconnecting the batteries.
2. In order to ensure a proper function of the regulator always
take care of an sufficient amount of cooling air throughflow.
3.2.6.1
Configuration via JETIBOX
After connecting the
SBEC
30D
to the
JETIBOX,
a startup screen
appears that contains identification of the device and the value of
consumed capacity of the battery in the first line of the JETIBOX
display. The second line contains the data (from the left) of the input