Notice:
1. Always follow the same procedure when switching on/off. To 
switch-on,  first  connect  the  batteries  and  then  use  the 
magnetic or RC switch to activate the unit. To switch-off, always 
use  the  magnetic  or  RC  switch  to  turn-off  the  unit  before 
disconnecting the batteries.
2. In order to ensure a proper function of the regulator always 
take care of an sufficient amount of cooling air throughflow.

2.4.4 Switch - RC switch

MAX BEC 2D PLUS

 supports on/off via RC Switch. It can be easily 

used in JETI DC/DS transmitters. 

1.

 Disconnect the connector with a lock on the three-wire cable and 

separate the magnetic switch. 

2.

 Connect 

MAX BEC 2D Plus

 with RC Switch (conrol output) using 

three-wire cable. 

3.

 Bind the RC Switch with your transmitter and configure it in main 

„menu/model/device explorer/RC switch”

.

12 EN

2.4.5 

Connection of MAX BEC 2D Plus telemetry to the 

Duplex receiver

Connect the three-wire cable (red JR connector) of the 

MAX BEC 2D 

Plus

  to  the 

Ext.  input

  of  the  Duplex  receiver.  For  Rx  receivers, 

please set the 

Ext. input

 as JETIBOX/Sensor. At newer REX receivers 

the Ext. input will be set automatically.

Telemetry of the MAX BEC 2D Plus:
MAX BEC 2D Plus

 sends the following values to the JETI DC/DS 

transmitter via the DUPLEX system: 

Acc. Input Volt

 – Shows the actual voltage of the power-supply 

batteries A and B.

Temperature

 – Shows the temperature of the MAX BEC 2D Plus.

Output voltage

 – Shows the actual voltage on the output

Содержание MAX BEC

Страница 1: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC User manual EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC...

Страница 2: ...ettingandLEDfunction 7EN 2 3 2Wiring 8EN 2 3 3Switch 8EN 2 3 4ParametersMAXBEC2 9EN 2 4 MAXBEC2Dplus 10EN 2 4 1OutputvoltagesettingandLEDfunction 10EN 2 4 2Wiring 10EN 2 4 3Switch Magneticswitch 11EN...

Страница 3: ...C30D 16EN 3 2 1Outputvoltagesetting 16EN 3 2 2 Wiring 16 EN 3 2 3Switch Magneticswitch 16EN 3 2 4Switch RCswitch 17EN 3 2 5Heatprotection 18EN 3 2 6 Setup 18 EN 3 2 6 1 Configuration via JETIBOX 18 EN...

Страница 4: ...ch uses LiXX cells to power it The regulator ensures that the power supply to the servos is constant at all times and the result is the same speed of movement of the servos regardlessofthestateofdisch...

Страница 5: ...oad occurs the output voltage decreases to zero untiltheshortcircuitoroverloadisremoved Its great advantage is that it allows the use of standard servos in systems designed for the so called High Volt...

Страница 6: ...is above 7 0 V all three green LEDs are ON While the cells are gradually discharging particularLEDsgoOFFdependingoninputvoltage lowerthen7V 6 7V 6 45V If the input voltage is under 6 5V the red LED go...

Страница 7: ...requested output voltage of the regulatorcan be adjustedin stepsof 5 0V 5 4 V 5 7V and 6 0V The MAX BEC 2 supply can consist of LiXX or NiXX cells For this purpose we recommend application of 2 LiXX...

Страница 8: ...ies is equal current is drawn from both of them and LEDs of batteries 1 and 2 are ON There exists no energy exchange between the batteries if the voltages of both batteries are different therefore bot...

Страница 9: ...e Output MPX connector Electronic switch LED Accu 1 2 Power input Accu 1 2 2 3 4 Parameters MAX BEC 2 Dimensions 100x29x16 mm Weight 85 g Recommended input voltage 5 5 8 4 V Input voltage max 16 V Out...

Страница 10: ...and 6 5V If the input voltage becomeslower than 6 5 V the red LED lights up indicating discharged cells This shows in case of 2S LiXX batteries that the voltage per cell decreased below 3 25V 2 4 2 Wi...

Страница 11: ...netickeyispresent buttheunitisnotswitchedonyet If the green LED is continuously active this indicates that the MAXBEC2D PLUS is active and ready to power your receiver and servos SafetyPrecautionsfort...

Страница 12: ...eand separatethemagneticswitch 2 Connect MAX BEC 2D Plus with RC Switch conrol output using three wirecable 3 Bind the RC Switchwith your transmitterand configure it in main menu model deviceexplorer...

Страница 13: ...r input voltage Pins for jumper selection of output voltage Output MPX connector LED Accu A B Power input Accu A B 13 EN 2 3 4 Parameters MAX BEC 2D plus Dimensions 100x29x16 mm Weight 85 g Recommende...

Страница 14: ...egulator SBEC comprises two battery input cables with cross sections of 1mm2 as well as two pairs of output servo cables with cross sections of 0 5mm2 each These output cablesareequippedwithJR plugs 3...

Страница 15: ...ustained current A 6 2 5 7 5 4 5 1 4 7 4 5 4 1 3 8 3 5 Sustainedcurrentvaluesarevalidonlyforoperatingconditions withsufficientcoolingairflow 3 1 5 ParametersSBEC Dimensions 60x28x10mm Weight 29g Recom...

Страница 16: ...e external switch such as Universal Magnetic Switch or RC Switch On the output there are two cables with cross sections of 2 5mm2 which are connected to the receiver via MPX connector In addition SBEC...

Страница 17: ...he magnetic switch and key Key Target Led ON SafetyPrecautionsfortheManipulationofMagnets Since the MAXBEC 2D Plus contains magnetic components it is necessary to follow some simple rules for the hand...

Страница 18: ...gher Otherwise the output voltage may decline during the load The switch on state of the regulator is signaled by thegreenLED Notice 1 Always make sure that all the connected devices such as receivers...

Страница 19: ...ection OutputVoltage actualvalueofBEC soutputvoltage Temperature actualtemperaturevalue in C Theitemsof MIN MAX Reset MIN MAX by pushing the arrows R and L left and right together the minimum and maxi...

Страница 20: ...sfromthesensors Only keep the pin disconnected or connected to the common groundoftheSBEC30D 1 Contact end switch Typ 40kW FIG 8 Example of logic input connection 20 EN Toswitchbetweenitems presslefto...

Страница 21: ...andnewer ThereceivermustbeconnectedtotheSBEC30DviaEXbus Transmitterfirmwareversion4 28andnewer FileSBEC30D binstoredinthe Devices folderonthetransmitter SDcard When everything is properly connected an...

Страница 22: ...citytakenfromthebattery Temperature actualtemperatureoftheBEC TelemetryMin Max Clear Min Max switch here you can assign a control on the DC DStransmitterwhichclearsbatterycapacityandtherecorded minimu...

Страница 23: ...ound in the user manualfortheUSBadapter oStarttheJETIStudioupdateprogramonyourPC o Connect the USB adapter via three wire cable to the main EXT of theSBEC30D redJRconnector o Connect the power supply...

Страница 24: ...EC30D Dimensions 72x28x14mm Weight 50g Recommendedinputvoltage 6 42V Inputvoltagemax 59V Outputvoltage 5 0V 8 4V Sustainedcurrent 8 2A withsupply 2SLiXX seetab Peakcurrent 30A max 1s Number of Lixx ce...

Страница 25: ...he assumption that it has been operated in conformity with these instructions at recommended voltages and that it has not been damaged mechanically Warranty and post warrantyserviceisprovidedbythemanu...

Страница 26: ...public The stated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic...

Страница 27: ...ated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic compatibilit...

Страница 28: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC JETI model s r o Lomen 1530 742 58 P bor Czech Republic www jetimodel com www jetimodel cz info jetimodel cz 28 EN...

Отзывы: