2.4.3 Switch  - Magnetic switch

The magnetic switch is designed to turn the 

MAX BEC 2D Plus

 on or 

off and is connected to it by a three-wire cable with a connector. To 
switch on the MAX BEC 2D Plus, it is necessary to place the supplied 
magnet in the carrier on the target so that the key of the carrier and 
the  key  on  the  magnetic  switch  are  the  same  orientation.  The 
magnetic switch has a green LED indicating "on".

 

G

reen LED “on”

 

- If the green LED is blinking, this indicates that the 

magnetic key is present, but the unit is not switched on yet.
-  If  the  green  LED  is  continuously  active,  this  indicates  that  the 
MAXBEC2D PLUS is active and ready to power your receiver and 
servos.

Safety Precautions for the Manipulation of Magnets:
Since the MAXBEC 2D Plus contains magnetic components, it is 
necessary  to  follow  some  simple  rules  for  the  handling  of 
magnets.  The  magnet  is  contained  within  a  special  holder 
made of aluminium.
1. Keep the magnet a safe distance from all devices that could 
be  damaged  by  magnetic  interference:  Televisions,  Credit 
Cards, PC's and Pacemakers!
2.  Keep  magnets  away  from  children,  due  to  the  risk  of 
ingestion or injury!

11 EN

FIG. 4: Description of the magnetic switch and key

Key

Target

Led ON

Содержание MAX BEC

Страница 1: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC User manual EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC...

Страница 2: ...ettingandLEDfunction 7EN 2 3 2Wiring 8EN 2 3 3Switch 8EN 2 3 4ParametersMAXBEC2 9EN 2 4 MAXBEC2Dplus 10EN 2 4 1OutputvoltagesettingandLEDfunction 10EN 2 4 2Wiring 10EN 2 4 3Switch Magneticswitch 11EN...

Страница 3: ...C30D 16EN 3 2 1Outputvoltagesetting 16EN 3 2 2 Wiring 16 EN 3 2 3Switch Magneticswitch 16EN 3 2 4Switch RCswitch 17EN 3 2 5Heatprotection 18EN 3 2 6 Setup 18 EN 3 2 6 1 Configuration via JETIBOX 18 EN...

Страница 4: ...ch uses LiXX cells to power it The regulator ensures that the power supply to the servos is constant at all times and the result is the same speed of movement of the servos regardlessofthestateofdisch...

Страница 5: ...oad occurs the output voltage decreases to zero untiltheshortcircuitoroverloadisremoved Its great advantage is that it allows the use of standard servos in systems designed for the so called High Volt...

Страница 6: ...is above 7 0 V all three green LEDs are ON While the cells are gradually discharging particularLEDsgoOFFdependingoninputvoltage lowerthen7V 6 7V 6 45V If the input voltage is under 6 5V the red LED go...

Страница 7: ...requested output voltage of the regulatorcan be adjustedin stepsof 5 0V 5 4 V 5 7V and 6 0V The MAX BEC 2 supply can consist of LiXX or NiXX cells For this purpose we recommend application of 2 LiXX...

Страница 8: ...ies is equal current is drawn from both of them and LEDs of batteries 1 and 2 are ON There exists no energy exchange between the batteries if the voltages of both batteries are different therefore bot...

Страница 9: ...e Output MPX connector Electronic switch LED Accu 1 2 Power input Accu 1 2 2 3 4 Parameters MAX BEC 2 Dimensions 100x29x16 mm Weight 85 g Recommended input voltage 5 5 8 4 V Input voltage max 16 V Out...

Страница 10: ...and 6 5V If the input voltage becomeslower than 6 5 V the red LED lights up indicating discharged cells This shows in case of 2S LiXX batteries that the voltage per cell decreased below 3 25V 2 4 2 Wi...

Страница 11: ...netickeyispresent buttheunitisnotswitchedonyet If the green LED is continuously active this indicates that the MAXBEC2D PLUS is active and ready to power your receiver and servos SafetyPrecautionsfort...

Страница 12: ...eand separatethemagneticswitch 2 Connect MAX BEC 2D Plus with RC Switch conrol output using three wirecable 3 Bind the RC Switchwith your transmitterand configure it in main menu model deviceexplorer...

Страница 13: ...r input voltage Pins for jumper selection of output voltage Output MPX connector LED Accu A B Power input Accu A B 13 EN 2 3 4 Parameters MAX BEC 2D plus Dimensions 100x29x16 mm Weight 85 g Recommende...

Страница 14: ...egulator SBEC comprises two battery input cables with cross sections of 1mm2 as well as two pairs of output servo cables with cross sections of 0 5mm2 each These output cablesareequippedwithJR plugs 3...

Страница 15: ...ustained current A 6 2 5 7 5 4 5 1 4 7 4 5 4 1 3 8 3 5 Sustainedcurrentvaluesarevalidonlyforoperatingconditions withsufficientcoolingairflow 3 1 5 ParametersSBEC Dimensions 60x28x10mm Weight 29g Recom...

Страница 16: ...e external switch such as Universal Magnetic Switch or RC Switch On the output there are two cables with cross sections of 2 5mm2 which are connected to the receiver via MPX connector In addition SBEC...

Страница 17: ...he magnetic switch and key Key Target Led ON SafetyPrecautionsfortheManipulationofMagnets Since the MAXBEC 2D Plus contains magnetic components it is necessary to follow some simple rules for the hand...

Страница 18: ...gher Otherwise the output voltage may decline during the load The switch on state of the regulator is signaled by thegreenLED Notice 1 Always make sure that all the connected devices such as receivers...

Страница 19: ...ection OutputVoltage actualvalueofBEC soutputvoltage Temperature actualtemperaturevalue in C Theitemsof MIN MAX Reset MIN MAX by pushing the arrows R and L left and right together the minimum and maxi...

Страница 20: ...sfromthesensors Only keep the pin disconnected or connected to the common groundoftheSBEC30D 1 Contact end switch Typ 40kW FIG 8 Example of logic input connection 20 EN Toswitchbetweenitems presslefto...

Страница 21: ...andnewer ThereceivermustbeconnectedtotheSBEC30DviaEXbus Transmitterfirmwareversion4 28andnewer FileSBEC30D binstoredinthe Devices folderonthetransmitter SDcard When everything is properly connected an...

Страница 22: ...citytakenfromthebattery Temperature actualtemperatureoftheBEC TelemetryMin Max Clear Min Max switch here you can assign a control on the DC DStransmitterwhichclearsbatterycapacityandtherecorded minimu...

Страница 23: ...ound in the user manualfortheUSBadapter oStarttheJETIStudioupdateprogramonyourPC o Connect the USB adapter via three wire cable to the main EXT of theSBEC30D redJRconnector o Connect the power supply...

Страница 24: ...EC30D Dimensions 72x28x14mm Weight 50g Recommendedinputvoltage 6 42V Inputvoltagemax 59V Outputvoltage 5 0V 8 4V Sustainedcurrent 8 2A withsupply 2SLiXX seetab Peakcurrent 30A max 1s Number of Lixx ce...

Страница 25: ...he assumption that it has been operated in conformity with these instructions at recommended voltages and that it has not been damaged mechanically Warranty and post warrantyserviceisprovidedbythemanu...

Страница 26: ...public The stated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic...

Страница 27: ...ated product complies with essential requirements of EMC 2014 30 EU RoHS Directive2011 65 EUand EU 2015 863 Harmonised standards applies Protection requirements concerning electromagnetic compatibilit...

Страница 28: ...EN MAX BEC SBEC MAX BEC SBEC MAX BEC SBEC JETI model s r o Lomen 1530 742 58 P bor Czech Republic www jetimodel com www jetimodel cz info jetimodel cz 28 EN...