6. Product selection
The product part number is composed of the product model number and suffixes indicating the full-
scale flow rate, as well as the other parameters. Refer to the following for details.
MF50 -
- - - - - - -
Note:
Explosive proof: Ex ia IIC T4 Gb.
Table 6.1: Mechanical connection and flow range of all models.
Model
DN
(mm)
Mechanical connection
Flow range
SLPM
m
3
/h
SCFM
MF5003
3.0
N1M: NPT 1/8 male
N1F: NPT 1/8 female
0.15 ~ 15
-
MF5006
6.0
N2M: NPT 1/4 male
N2F: NPT 1/4 female
0.5 ~ 50
0.03 ~ 3
0.02 ~ 2
MF5008
8.0
N3M: NPT 3/8 male
N3F: NPT 3/8 female
1.2 ~ 120
0.072 ~ 7.2
0.05 ~ 5
MF5012
12.0
N4M: NPT 1/2 male
N4F: NPT 1/2 female
3 ~ 300
0.18 ~ 18
0.1 ~ 10
MF5019
19.0
N6M: NPT 3/4 male
N6F: NPT 3/4 female
8 ~ 800
0.48 ~ 48
0.3 ~ 30
e.g.
MF5006-N2F-E-0.5-5-15-AB-D-A
Gas: A
–
air; C
–
CO
2
; N
–
N2; O
–
O2; R- Ar.
for other gases, please contact the manufacturer.
Output: A - 4 ~ 20 mA, B - RS485 Modbus, N
–
null.
Option: N, B or AB.
Maximum flow rate: Refer to table 6.1.
Mechanical connection: Refer to table 6.1.
DN: refer to table 6.1.
Display: D
–
LCD; N
–
null.
Minimum flow rate: Refer to table 6.1.
Hazardous rating: E
–
Ex proof; e
–
Null.
Maximum working pressure: 15
–
15 bar (1.5 MPa)
29
|
P
a
g
e
http://www.jetec.com w
om.tw/
.t
電話:
0
4
-
23729418 傳真:04-23724011 Email:[email protected] LINE:@jetec