background image

 

1.0  IMPORTANT SAFETY 

INSTRUCTIONS 

When  using  an  electrical  appliance,  basic 
precautions  should  always  be  followed,  including 
the following: 

READ ALL INSTRUCTIONS BEFORE USING THIS 
AIR FILTRATION UNIT. 

 To  reduce  the  risk  of  fire, 

electric shock, or injury: 

1. 

Read  and  understand  the  entire  owner's 
manual  before  attempting  assembly  or 
operation. 

2. 

Read and understand the warnings posted 
on the machine and in this manual. Failure 
to  comply  with  all  of  these  warnings  may 
cause serious injury. 

3. 

Replace the warning labels if they become 
obscured or removed. 

4. 

Do not use this air filtration system for other 
than  its  intended  use.  If  used  for  other 
purposes, JET disclaims any real or implied 
warranty and holds itself harmless from any 
injury that may result from that use. 

5. 

Never  duct  a  machine  directly  into  the  air 
filtration unit. 

6. 

To avoid a potentially dangerous situation, 
do  not  use  this  equipment  to  filter  volatile 
fumes or smoke. 

7. 

Do  not  use  this  equipment  to  filter 
flammable vapors. This air filtration unit is 
designed  and  intended  for  the  filtration  of 
air  borne  dust  only.  It  is  neither  designed 
nor  intended  for  any  other  purpose 
whatsoever. 

8. 

Keep visitors a safe distance from the work 
area. Keep children away. 

9. 

Make  your  workshop  child  proof  with 
padlocks, master switches or by removing 
starter keys. 

10. 

DRUGS,  ALCOHOL,  MEDICATION.

    Do 

not  operate  tool  while  under  the  influence 
of drugs, alcohol or any medication. 

11. 

Make  certain  the  switch  is  in  the  OFF 
position before connecting the machine to 
the power supply. 

12. 

Make  certain  the  machine  is  properly 
grounded. 

13. 

Use  recommended  accessories;  improper 
accessories may be hazardous. 

14. 

GROUND ALL TOOLS.  

If tool is equipped 

with three prong plug, it should be plugged 

into a three-hole electrical receptacle. If an 
adapter  is  used  to  accommodate  a  two-
prong receptacle, the adapter lug must be 
attached to a known ground. Never remove 
the third prong. 

15. 

WARNING

:  Drilling,  sawing,  sanding  or 

machining wood products generates wood 
dust  and  other  substances  known  to  the 
State  of  California  to  cause  cancer.  Avoid 
inhaling  dust  generated  from  wood 
products  or  use  a  dust  mask  or  other 
safeguards 

to 

avoid 

inhaling 

dust 

generated  from  wood  products.  Wood 
products emit chemicals known to the State 
of California to cause birth defects or other 
reproductive  harm.  (California  Health  and 
Safety Code Section 25249.6) 

16. 

Keep  safety  guards,  panels,  and  doors  in 
place,  secured,  and  always  closed  when 
the  machine  is  in  use.  If  removed  for 
maintenance  purposes,  use  extreme 
caution and replace the guards, install the 
panels  and  close  the  doors  immediately 
after completion of maintenance. 

17. 

Maintain tools with care. Keep filters clean 
for the best and safest performance. 

18. 

Turn off the machine before cleaning. Use 
a brush or compressed air to remove chips 
or debris 

 do not use your hands. 

19. 

Do  not  use  this  air  filtration  unit  with  a 
damaged  cord  or  plug.  If  the  unit  is  not 
working  as  it  should,  has  been  dropped, 
damaged,  left  outdoors,  or  dropped  into 
water, return it to a service center. 

20. 

When  ceiling  mounted,  bottom  of  filtration 
unit must be at least 7 feet from the floor. 
The  mounts must be anchored to building 
structure  which  will  support  the  weight  of 
the  air  filtration  unit.  Never  mount  to 
surfaces  such  as  dry  wall  or  false  ceiling 
grids. 

21. 

When bench top mounted, do not place this 
unit on an unstable surface, or where there 
is a risk of tipping over. Serious injury could 
occur if the unit tips over. 

22. 

To  reduce  risk  of  electric  shock,  do  not 
expose filtration unit to water or rain. 

23. 

Do not use in high humidity environments. 
Doing so may cause electric shock and/or 
decreased performance of the unit. 

24. 

WARNING:

  Not suitable for use with solid-

state speed controls. 

25. 

Suitable  for  commercial  or  industrial  use 
only. 

 

 

 

 

Содержание AFS-1000C

Страница 1: ... 427 New Sanford Road LaVergne Tennessee 37086 Part No M 713000 Ph 800 274 6848 Edition 3 12 2021 www jettools com Copyright 2021 JET Operating Instructions and Parts Manual AFS 1000C Air Filtration System ...

Страница 2: ...sed to accommodate a two prong receptacle the adapter lug must be attached to a known ground Never remove the third prong 15 WARNING Drilling sawing sanding or machining wood products generates wood dust and other substances known to the State of California to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from ...

Страница 3: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique ...

Страница 4: ...0 Operation 12 10 0 User maintenance 13 10 1 Changing the Filters 13 10 2 Cleaning the Filters 13 10 2 1 Washable Filters 13 10 2 2 Dry Filters 14 10 3 RF Remote Control Replacement 14 10 4 Cleaning Sensors 14 10 5 Sensor Replacement 14 10 6 Control Board Replacement 14 11 0 Troubleshooting 15 12 0 Replacement Parts 16 12 1 1 AFS Unit Exploded View 16 12 1 2 AFS Unit Parts List 17 12 2 1 Display M...

Страница 5: ...tended to be an exhaustive guide to air filtration systems Additional knowledge can be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual for future reference If the machine ...

Страница 6: ...CE o Fan Speed 6 levels o Timer setting 1 to 16 hours in 1 hour increments automatically shuts off when timer runs out High efficiency Brushless DC motor o Improved durability o Quieter operation o More energy efficient Auto Mode o In Auto Mode the unit monitors ambient air quality using an integrated PM2 5 sensor and adjusts fan speed to compensate o More air flow when it s needed to quickly impr...

Страница 7: ...125V Overload protector 5A Performance Fan Speed Air flow without filter CFM 1 Sound rating 1m 1 1 450 10 51dB 2 560 10 56dB 3 670 10 60dB 4 780 10 63dB 5 890 10 66dB 6 1000 10 67dB Control Panel On off switch Rocker switch Speed control Six selectable speeds Timer Setting Hour 1 16 LED display Display LED module Digital Remote Control Transmitter Radio Frequency Battery CR2032 3 Volt Button Cell ...

Страница 8: ...eight lbs 41 8lbs 19 kg 1 Variable of 10 for general information only not to be viewed as fixed parameters for inspection purposes L length W width H height n a not applicable The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice without incurring...

Страница 9: ... be capable of supporting the weight of the air filtration unit and absorbing any vibrations arising from the unit Appropriate fasteners must be used to secure to the ceiling Failure to comply may cause serious injury Never mount to surfaces such as dry wall false ceiling grids etc When overhead mounting such as a ceiling make sure chain and ceiling hooks are properly rated for hanging this unit R...

Страница 10: ...reen with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Failure to comply...

Страница 11: ...ing AFS unit goes to STANDBY state All DISPLAYS are off and the fan stops TIMER control panel or remote The TIMER buttons Fig 8 1 and 8 2 on the controls and the remote perform the exact same function under the exact same conditions The TIMER may be set in 1 hour increments from 1 to 16 hours When the timer expires the fan will stop and the AFS will enter STANDBY state When the timer is not being ...

Страница 12: ...e AUTO mode and return to manual mode NOTE In AUTO mode the unit may require several minutes to return to fan speed 1 once dust is detected The unit intentionally ramps down slowly to ensure good shop air quality FILTER STATUS INDICATOR control panel The FILTER status indicators are located on the control panel and are there to indicate the condition of the filters GOOD indicates that the filters ...

Страница 13: ... To reduce the risk of injury disconnect the air filtration system from the power source unplug before servicing or changing filters Failure to comply may cause serious injury This AFS is designed to remove airborne non metallic dust particles from the air Cleaning is about removing those particles from the filter in the opposite direction from which it came It is recommended to clean both filters...

Страница 14: ...he ON OFF button 3 Press and hold the SPEED minus and SPEED plus buttons on the control panel at the same time and hold for two seconds The screen flashes 0 5 seconds and displays to enter the programming mode 4 Press and hold the ON OFF button of the REMOTE control until the panel is turned ON ON is displayed and the programming is complete 5 In the programming mode press any other button on the ...

Страница 15: ...dentify sources of interference and eliminate them or relocate unit Remote control or machine control panel malfunction Contact JET customer service Unit not working efficiently not cleaning air Filter not installed properly Reinstall filter Blocked air flow Inspect filter replace if clogged remove blockage Controls on unit not working Control button or PCBA malfunction Contact JET customer servic...

Страница 16: ...s To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately 12 1 1 AFS Unit Exploded View ...

Страница 17: ...ssembly SEE 12 3 1 for detail 1 21 AFS1000C 021 Eye bolt M6X20 4 22 AFS1000C 022 Standoff M6X25 4 23 TS 1550041 Flat washer M6 13 24 TS 1534032 Screw Pan Head Phillips M6X10 5 25 TS 2286202 Screw Pan Head Phillips M6X20 2 26 AFS1000C 023 Hex head bolt M6X300 6 27 TS 1551041 Spring washer M6 7 28 AFS1000C 024 Screw Pan Head Phillips Tapping screw M5X12 8 29 AFS1000C 025 Flat head screw Tapping scre...

Страница 18: ...isplay Module Assembly 1 8 1 AFS1000C DM1 AC power switch 1 8 2 AFS1000C DM2 Display label 1 8 3 AFS1000C DM3 Auto button 1 8 4 AFS1000C DM4 Display cover 1 8 5 AFS1000C DM5 Display PCB 1 8 6 AFS1000C DM6 Screw Pan Head Phillips Tapping screw M3X6 6 8 7 AFS1000C DM7 Control module 1 8 8 AFS1000C DM8 Screw Pan Head Phillips Tapping screw M4X10 4 ...

Страница 19: ...escription Size Qty 20 AFS1000C RCA Remote Control Assembly 1 20 1 AFS1000C RC1 Remote label 1 20 2 AFS1000C RC2 Remote front case 1 20 3 AFS1000C RC3 Remote PCB 1 20 4 AFS1000C RC4 Button cell CR2032 1 20 5 AFS1000C RC5 Remote rear case 1 20 6 AFS1000C RC6 Battery cover 1 20 7 AFS1000C RC7 Remote FCC label 1 ...

Страница 20: ...20 13 0 Electrical Connections 115V Power Switch Display PCB CN1 CN2 CN2 Control Module Motor Thermal Fuse Power Cord Dust Sensor ...

Страница 21: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Страница 22: ...22 NOTES ...

Страница 23: ...23 NOTES ...

Страница 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...