background image

 13

10.0  User-maintenance 

 Always  disconnect  power  to 

the  machine  before  performing  maintenance. 
Failure to do this may result in serious personal 
injury. 

10.1  Changing the Filters 

 

 To  reduce  the  risk  of  injury, 

disconnect  the  air  filtration  system  from  the 
power  source  (unplug)  before  servicing  or 
changing  filters.  Failure  to  comply  may  cause 
serious injury! 

There are two filters that need to be changed. 

Filter life will vary depending on the amount of usage 
and  the  environment  of  your  shop.  Clogged  filters 
will reduce the amount of air circulation. 

1.  Lift the filter up and pull outward on the bottom 

edge to remove the filter. 

 

Figure 10-1 

2.  Remove the 

inner filter

 by pulling straight out of 

the cabinet. 

3.  Remove any protective wrapping from the new 

filters.  

4.  Install the filters in reverse of the removal. The 

outer filter has directional air flow arrows printed 
on the frame which depicts the direction of air 
flow. Make sure it is facing the proper direction 
when  installed.  If  no  directional  arrows  are 
present,  the  inboard  side  of  the  filter  will 
typically  have  metal  support  not  used  on  the 
outboard side. 

 

Replacement Filters: 

NOTE:

 JET brand filters are recommended for best 

performance.  

708731 ...... Electrostatic Outer Filter 
708732 ...... Washable Electrostatic Outer Filter 
708733 ...... Inner Three-Pocket Filter 
708734 ...... Charcoal Filter 

 

 

10.2  Cleaning the Filters 

 To  reduce  the  risk  of  injury, 

disconnect  the  air  filtration  system  from  the 
power  source  (unplug)  before  servicing  or 
changing  filters.  Failure  to  comply  may  cause 
serious injury! 

This  AFS  is  designed  to  remove  airborne  non-
metallic dust particles from the air. Cleaning is about 
removing  those  particles  from  the  filter  in  the 
opposite direction from which it came. 

It is recommended to clean both filters at the same 
time. Whether using the Filter Status Indicator or a 
visual  inspection,  both  filters  should  be  cleaned  to 
restore as much filtration ability as possible. 

Remove the filters from the AFS unit as described 
in 10.1 Changing the Filters. 

10.2.1  Washable Filters 

Washable filters are those filters which may get wet 
and allowed to dry before returning to service. The 
replacement  Washable  Electrostatic  Outer  Filter 
(P/N 708732) is a washable filter. 

 

Figure 10-2 Inside of filter shown. 

 

Using a hose and spray nozzle with normal tap 
water pressure, spray the filter from the inside 
out.  Opposite  the  operating  air  flow.  This  will 
rinse the larger loose particles out of the filter. 

 

Mix a mild detergent and water mixture (soap) 
such  as  dish  soap.  Mix  a  drop  or  two  of  dish 
soap  and  water  into  a  spray  bottle.  If  using  a 
commercial  electrostatic  detergent,  follow  the 
label instructions. 

 

Spray  the  soap  onto  the  entire  filter  until  fully 
covered. 

 

Allow  the  soap  to  soak  1  to  2  minutes  on  the 
filter but do not allow the soap to dry. This will 
create a sticky film that is difficult to remove. 

 

Thoroughly  rinse the soap out of the filter and 
the filter frame. 

Содержание AFS-1000C

Страница 1: ... 427 New Sanford Road LaVergne Tennessee 37086 Part No M 713000 Ph 800 274 6848 Edition 3 12 2021 www jettools com Copyright 2021 JET Operating Instructions and Parts Manual AFS 1000C Air Filtration System ...

Страница 2: ...sed to accommodate a two prong receptacle the adapter lug must be attached to a known ground Never remove the third prong 15 WARNING Drilling sawing sanding or machining wood products generates wood dust and other substances known to the State of California to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from ...

Страница 3: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique ...

Страница 4: ...0 Operation 12 10 0 User maintenance 13 10 1 Changing the Filters 13 10 2 Cleaning the Filters 13 10 2 1 Washable Filters 13 10 2 2 Dry Filters 14 10 3 RF Remote Control Replacement 14 10 4 Cleaning Sensors 14 10 5 Sensor Replacement 14 10 6 Control Board Replacement 14 11 0 Troubleshooting 15 12 0 Replacement Parts 16 12 1 1 AFS Unit Exploded View 16 12 1 2 AFS Unit Parts List 17 12 2 1 Display M...

Страница 5: ...tended to be an exhaustive guide to air filtration systems Additional knowledge can be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual for future reference If the machine ...

Страница 6: ...CE o Fan Speed 6 levels o Timer setting 1 to 16 hours in 1 hour increments automatically shuts off when timer runs out High efficiency Brushless DC motor o Improved durability o Quieter operation o More energy efficient Auto Mode o In Auto Mode the unit monitors ambient air quality using an integrated PM2 5 sensor and adjusts fan speed to compensate o More air flow when it s needed to quickly impr...

Страница 7: ...125V Overload protector 5A Performance Fan Speed Air flow without filter CFM 1 Sound rating 1m 1 1 450 10 51dB 2 560 10 56dB 3 670 10 60dB 4 780 10 63dB 5 890 10 66dB 6 1000 10 67dB Control Panel On off switch Rocker switch Speed control Six selectable speeds Timer Setting Hour 1 16 LED display Display LED module Digital Remote Control Transmitter Radio Frequency Battery CR2032 3 Volt Button Cell ...

Страница 8: ...eight lbs 41 8lbs 19 kg 1 Variable of 10 for general information only not to be viewed as fixed parameters for inspection purposes L length W width H height n a not applicable The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice without incurring...

Страница 9: ... be capable of supporting the weight of the air filtration unit and absorbing any vibrations arising from the unit Appropriate fasteners must be used to secure to the ceiling Failure to comply may cause serious injury Never mount to surfaces such as dry wall false ceiling grids etc When overhead mounting such as a ceiling make sure chain and ceiling hooks are properly rated for hanging this unit R...

Страница 10: ...reen with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Failure to comply...

Страница 11: ...ing AFS unit goes to STANDBY state All DISPLAYS are off and the fan stops TIMER control panel or remote The TIMER buttons Fig 8 1 and 8 2 on the controls and the remote perform the exact same function under the exact same conditions The TIMER may be set in 1 hour increments from 1 to 16 hours When the timer expires the fan will stop and the AFS will enter STANDBY state When the timer is not being ...

Страница 12: ...e AUTO mode and return to manual mode NOTE In AUTO mode the unit may require several minutes to return to fan speed 1 once dust is detected The unit intentionally ramps down slowly to ensure good shop air quality FILTER STATUS INDICATOR control panel The FILTER status indicators are located on the control panel and are there to indicate the condition of the filters GOOD indicates that the filters ...

Страница 13: ... To reduce the risk of injury disconnect the air filtration system from the power source unplug before servicing or changing filters Failure to comply may cause serious injury This AFS is designed to remove airborne non metallic dust particles from the air Cleaning is about removing those particles from the filter in the opposite direction from which it came It is recommended to clean both filters...

Страница 14: ...he ON OFF button 3 Press and hold the SPEED minus and SPEED plus buttons on the control panel at the same time and hold for two seconds The screen flashes 0 5 seconds and displays to enter the programming mode 4 Press and hold the ON OFF button of the REMOTE control until the panel is turned ON ON is displayed and the programming is complete 5 In the programming mode press any other button on the ...

Страница 15: ...dentify sources of interference and eliminate them or relocate unit Remote control or machine control panel malfunction Contact JET customer service Unit not working efficiently not cleaning air Filter not installed properly Reinstall filter Blocked air flow Inspect filter replace if clogged remove blockage Controls on unit not working Control button or PCBA malfunction Contact JET customer servic...

Страница 16: ...s To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately 12 1 1 AFS Unit Exploded View ...

Страница 17: ...ssembly SEE 12 3 1 for detail 1 21 AFS1000C 021 Eye bolt M6X20 4 22 AFS1000C 022 Standoff M6X25 4 23 TS 1550041 Flat washer M6 13 24 TS 1534032 Screw Pan Head Phillips M6X10 5 25 TS 2286202 Screw Pan Head Phillips M6X20 2 26 AFS1000C 023 Hex head bolt M6X300 6 27 TS 1551041 Spring washer M6 7 28 AFS1000C 024 Screw Pan Head Phillips Tapping screw M5X12 8 29 AFS1000C 025 Flat head screw Tapping scre...

Страница 18: ...isplay Module Assembly 1 8 1 AFS1000C DM1 AC power switch 1 8 2 AFS1000C DM2 Display label 1 8 3 AFS1000C DM3 Auto button 1 8 4 AFS1000C DM4 Display cover 1 8 5 AFS1000C DM5 Display PCB 1 8 6 AFS1000C DM6 Screw Pan Head Phillips Tapping screw M3X6 6 8 7 AFS1000C DM7 Control module 1 8 8 AFS1000C DM8 Screw Pan Head Phillips Tapping screw M4X10 4 ...

Страница 19: ...escription Size Qty 20 AFS1000C RCA Remote Control Assembly 1 20 1 AFS1000C RC1 Remote label 1 20 2 AFS1000C RC2 Remote front case 1 20 3 AFS1000C RC3 Remote PCB 1 20 4 AFS1000C RC4 Button cell CR2032 1 20 5 AFS1000C RC5 Remote rear case 1 20 6 AFS1000C RC6 Battery cover 1 20 7 AFS1000C RC7 Remote FCC label 1 ...

Страница 20: ...20 13 0 Electrical Connections 115V Power Switch Display PCB CN1 CN2 CN2 Control Module Motor Thermal Fuse Power Cord Dust Sensor ...

Страница 21: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Страница 22: ...22 NOTES ...

Страница 23: ...23 NOTES ...

Страница 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Отзывы: