![Jet 3520B Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/jet/3520b/3520b_operating-instructions-manual_645226007.webp)
Warning:
The AC Inverter does not require any
programming. It is pre-programmed
from the factory. The buttons and
knob on the face of inverter should not
be changed.
7.2 Headstock spindle lock
Push in pin (E, Fig 27) to keep the
spindle from turning.
Fig 27
Caution:
Never press the spindle lock while the
spindle is turning!
7.3 Headstock spindle index
Thread indexing pin (Fig 28) into one
of the headstock threadholes (A;B;C;D,
Fig 29).
Make sure that it locates in the spindle
hole.
Fig 28
There are 12 holes in the spindle 30°
apart.
Fig 29
The combination of these holes will
allow you to locate your workpiece in
10° or 15° increments (for different
hole patterns see appendix A at the
end of this manual).
7.4 Installing work holding
The faceplate
is used for tuning
bowls. There are a number of holes for
mounting the workpiece.
Thread the faceplate onto the spindle
in a clockwise direction, and tighten
two set screws (Fig 30).
Fig 30
Remove the faceplate by loosening
two setscrews. Push in the spindle lock
and use the provided wrench (F, Fig
27).
7.5 Adjusting tool rest
Position the tool rest as close to the
workpiece as possible. Tighten handle
(C, Fig 31) to lock.
Set the height to appr. 3mm above
centreline. Tighten indexable knob (D).
Fig 31
7.6 Adjusting tailstock
Turn the hand wheel (P, Fig 32)
clockwise to move tailstock spindle
forward. Lock tailstock spindle with the
indexable knob (O).
Fig 32
The handle (Q) locks the tailstock in
position on the bed.
The live centre can be ejected by
turning the hand wheel counter-
clockwise.
To screw off the cone (R, Fig 33) the
life center must be locked against
rotation with the supplied pin (S).
Fig 33
The centering pin can be knocked out
to allow deep hole drilling operations.
8. Maintenance and inspection
General notes:
Maintenance, cleaning and repair
work may only be carried out after
the machine is protected against
accidental starting by pulling the
mains plug.
Clean the machine regularly.
Remove any foreign objects from the
heat sinks of AC-drive (Do not obstrukt
the air flow).
Inspect the proper function of the dust
collection daily.
Defective safety devices must be
replaces immediately.
Repair and maintenance work on the
electrical system may only be carried
out by a qualified electrician.
(Warning: Wait five minutes for DC-
bus capacitors discharge before
accessing the AC drive unit!)