![Jet Power FILTER II Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/jet-power/filter-ii/filter-ii_operation-and-maintenance-manual_3775571011.webp)
OPERATION AND MAINTENANCE MANUAL PN 28.04.1014 GPU JET-POWER FILTER II 2500 PN 28.09.1013
PAGE 11/43
1.2.3.2 -
INPUT CABLE (see item 1.2.1)
Placed on the bottom left of the front cover. It comes with 25m of length
(it can be ordered with other lengths). Normally brand “PRYSMIAN”,
CORDPLAST type, 4x10mm
2
of gauge.
The neutral is connected internally to the BLUE cable.
After some years of use this cable may break close to the passage rubber,
internally, due to a great number of flexions. This could cause phase or
neutral failure. If that occurs cut the cable close to the entrance and re-
connect.
1.2.4 -
FRONT PANEL
1.2.4.1 -
VENTILATION GRID
Provides the exit of heated air pulled out by internal fans.
NOTE:
The grid must never be blocked.
1.2.4.2 -
OUTPUT CABLES (see item 1.2.1)
The socket for the aircraft´s output source (28V) is located on the left
side.
At the Center are placed the output connector to substitute the battery
(28V) and the differentiated output of less 9V (24V).
1.2.5 -
SIDES
1.2.5.1 -
HOOKS TO HOLD CABLES
It comes with hooks on both sides to hank the input cable on one side
and the output cables on the other side.
To prevent damage to the equipment avoid collisions with the hooks
while moving it.