5.9.2 Info Alarms
Info alarms indicate that there were one or more errors detected during last run.
Note
: The turbine must reach the running stage for info alarms to be registered.
“
Temp_Sens
” indicates a temperature probe failure.
“
Low_Temp
” indicates that the running temperature dropped below 100°C.
“
Max_Temp
” means that temperature exceeded 900°C
“
Batt_Rx
” Indicates that voltage from RX dropped below 4.5 volts.
“
Bat_ECU
” means that ECU battery voltage dropped below 8.4 volts.
“
Acc._Error
” appears when turbine is about to flameout because of a too
aggressive acceleration setting. When this happens the ECU automatically
increases the
“acceleration time” parameter by 1 point.
“
Max_Pump
” means that the pump reached its maximum power setting
without reaching the maximum turbine RPM.
“
Over_Amp
” indicates that the ECU current consumption exceeded the
maximum programmed limit.
“
Service
” indicates that the 25 hours of running time has elapsed and it needs
to go back to service immediately.
“
Void_Waran
” is displayed when 28 hours of running time has elapsed without
service; the Jet Central warranty is void at this point.
5.9.3 Turbine Status Messages
In the main screen you can see the status messages displayed in
Blue
text, they will indicate what the
turbine is doing during start up and running, status codes are as follows:
Manual Cooling
To initiate manual cooling lower the trim and raise the throttle to full.
Auto Cooling
When the EGT temperature is over 100°C and trim and throttle stick are in low
position, auto cooling will engage, if you aborted a startup, you need to cycle the trim
from low to high back to low.
Igniter heating
When the internal ceramic igniter is powered, pre heat time is factory set for 5-8
seconds.
Ignition
Kerosene ignition phase and the heating of the combustion chamber.
Preheat
An increase of rpm and fuel occurs to increase temperature inside the turbine.
Switchover
Phase of switching the kerosene feed from igniter to normal injectors.
To Idle
The phase of the acceleration cycle prior to idle speed being reached.
Running
Turbine working correctly, throttle control passed back to transmitter stick.
Stop Error
Start process aborted by alarms.
Stop
Normal Turbine shut down via user command (Tim Low , Stick Low).