6.3.3 Selection of advanced parameters, Job administration
Section Frontpanel „UNO“ for selection of advanced parameters and
for Job administration
Fig. 6-8
With the advanced parameters, factory settings for various welding applications can be
adapted (see description of advanced parameters ).
Selecting and editing advanced parameters
•
Press the key (P) longer than 3 seconds until first green LED and the textdisplay is lit.
A welding process can no longer be started.
•
You are now on the parameter " pre-gas time " ( first symbol left with the gas bottle )
•
By pressing key (P) for a short time move to the next parameter
•
Change the values by pressing the keys (U) and (D) or with the rotary knobs in
sections and
.
•
Selectable parameters are related to the selected
selected
operating mode
•
To exit the menu, press and hold the key (P) for approx. 2 seconds. LED and display
extinguish. All changes are stored. A new welding process can be started.
U
D
S
Text display
P
press short :
job selection
press long :
store job
Press long :
Activation of
editing mode
for advanced
parameters
Press short :
Move to next
parameter
Press long
again :
Exit editing
mode and
store all
changes
Indication which parameter is visible
on the textdisplay
Display for values of advanced
parameters
Selection of special characteristics
5
7
Scroll down Job list
Scroll up Job list
8