Technical Data
Capacity:
7 – 400 ml/h
(water at 20° C (68° F), suction height 1.7 m)
Pump tube:
0.8 x 1.6 mm
Recommended
operation time:
up to 8 h/d
Duty cycle:
100 %/h, if adjusted to <1/3 of max speed
50 %/h, if adjusted to >1/3 of max speed
of the recommended operation time
System back pressure:
2 bar (29 psig) max.
Ambient temperature:
10 - 50° C (50 - 122° F
Operating voltage:
180-264 VAC, 50-60 Hz (200-240 VAC +/-10%)
Fuse:
200 mA, semi-delay, 5 x 20 mm
Power consumption:
16 VA max.
Tube connections:
Clamping connection for hoses 4/6 mm
Dimensions:
92 x 170 x 130 mm (W x H x D)
Weight:
1.2 kg (2.65 Ibs.)
Installation and safety regulations
•
Pump must be installed in a place protected from mechanical impact, vapours,
acids and lyes.
•
Pump must be installed above the level of the barrel or supply tank, containing the
product.
•
Pump must be installed vertically with tube connections facing downward.
•
CAUTION!
The pump must not be used for inflammable products! When pumping dangerous
products such as acids, lyes, chlorous or biotechnological products all regulations
concerning the product have to be obeyed and all safety measures have to be
carried out. Special safety measures (for example collecting basin) are necessary in
case of damage of the pump tube to prevent damages and to inhibit any danger to
persons and environment.
Installations having tall delivery heights must be designed with pumps mounted so
that suction lift is smaller than pressure head. Peristaltic pumps work better when
operating against design system back pressure.
Each meter of height increases
the resulting pressure by 0,1 bar (with waterlike fluids).
•
If pump discharges into pressurized system, a check valve has to be installed.
CAUTION!