background image

14

GB

GB

GB

GB

GB

factory. If necessary, the rate of delivery can be adjusted by potentiometers P1 and P2 in
the range, that is specified in the chapter ”Technical Data“. If a different mode of
operation is required, refer to section „setting mode of operation“.

Safety in case of a ruptured pump tube

When using 

electrical conductive process fluid

, a damage of the pump tube is detected

by electrodes. If the level of the escaping process fluid in the pump housing reaches the
electrodes, the pump is switched off and an failure signal is activated. If 

a process fluid

with very low electrical conductivity

 is metered and the rupture of a tube occurs inside

the pump housing, the escaping process fluid can be drained with the help of an
additional tube that is connected to a tube fitting in the center of the tube retainer.

Maintenance / Wearing parts / Spare parts

The pump tube is a wearing part and has to be exchanged on a regular basis. The
maintenance of the chemical feed system is limited to the exchange of this tube, which
can be done during normal service.

NOTICE!
Before installing the EASYDOS Perestaltic V the chemical compatibility of the tube
and the process fluid has to be evaluated.

The life span of the pump tube depends on its chemical compatibility and the actual
periods of operation.
Spare tube: 138-0.8x1.6 *PharMed

® 

 

, system back pressure max. 2 bar; 7-400 ml/h

Part number: 37041

Chemical compatibility of the PharMed

® 

-pump tube with the following process fluids:

Aluminum chloride 53%

very good

Aluminum sulfate 50%

very good

Ferrous chloride 43%

very good

Ferrous sulfate 5%

very good

Sodium hydroxide 40%

very good

Sodium hypochloride 12%

very good

Hypochloric acid 10%

very good

Hypochloric acid 37%

good

Sulfuric acid 30%

very good

Sulfuric acid 96%

unsuitable

Hydrogen peroxide 30%

very good

Hydrogen peroxide 90 %

good

For other media please ask the pump manufacturer for the chemical resistance.

Spare parts are available that can be ordered in case of mechanical failure. When
ordering spare parts please specify the type of the unit and the serial number.
Spare parts
Tube retainer 0.8x4x1

part no. 37040

Rotor with rolls

part no. 37042

*PharMed

®  

is a registered trade mark of Saint-Gobain Performance Plastics.

NOTICE!

Содержание EASYDOS Peristaltic V

Страница 1: ...nance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Read these operation maintenance instructions before start up To be held for future re...

Страница 2: ...f operation 9 Mode of operation 1 adjustable rate of delivery 9 Mode of operation 2 one or two time relays 10 Mode of operation 3 1 time relay with adjustable rate of delivery on channel 1 12 Mode of...

Страница 3: ...azardous situation Non compliance can lead to death or serious injury CAUTION Refers to a potentially hazardous situation Non compliance can lead to minor injury or property damage NOTICE Appears in c...

Страница 4: ...1 Potentiometer P1q Q Potentiometer P2 Error signal L3 case fixing screw 6 Table with jumper positions Pump housing 7 Rotor Pump tube Inner electronic cover 10 Cover of electronic removed End splices...

Страница 5: ...table between 7 ml h and 400 ml h due to the high torque capabilities of the DC motor applicable even for smallest capacities against pressure of up to 2 bar 29 psig or 10 m 32 8 ft water column or vi...

Страница 6: ...level of the barrel or supply tank containing the product Pump must be installed vertically with tube connections facing downward CAUTION The pump must not be used for inflammable products When pumpi...

Страница 7: ...rminal block arrangement in the upper part of the installation housing Fasten union nut of the threaded cable gland A high IP Protection class is only achieved in this way Place device on installation...

Страница 8: ...re on the right side If another mode of operation is required pull jumper upwards with a forceps and put it onto the pin couple that corresponds to the desired mode of operation Mode of operation 1 ad...

Страница 9: ...inals 9 and 10 may be added NOTICE If no suction pipe with float switch is installed terminals 11 and 12 must be jumped With active control voltage on terminal 4 In2 terminals 5 neutral and 6 phase ar...

Страница 10: ...he warning signal are designated A jumper must be set that the pin marked with B and the pin in the middle are connected In this operation mode the operation time is started with an impulse that last...

Страница 11: ...ect selection selector switch SW in position 2 can be set With potentiometer P2 the rotor speed may be adjusted to a rate of delivery between 0 1 and 2 ml min With a control voltage 230 V AC at termin...

Страница 12: ...ter P2 the rotor speed can be set to operate at a rate of delivery between 0 1 and 2 ml min As long as the control current 230 V AC at terminal 4 is active the pump operates at the adjusted rate of de...

Страница 13: ...which can be done during normal service NOTICE Before installing the EASYDOS Perestaltic V the chemical compatibility of the tube and the process fluid has to be evaluated The life span of the pump t...

Страница 14: ...ys disconnected from the power supply while exchanging the tube switch off power supply of the chemical feed system The pump housing is a wearing part and must be changed after reasonable periods of t...

Страница 15: ...his declaration loses its validity Product description Perestaltic Pump Model designation EASYDOS Peristaltic V Relevant EC regulations EC Low Voltage Directive 73 23 EEC EC Electromagnetic Compatibil...

Страница 16: ...g Yes No Corrosive Yes No We hereby certify that the product has been cleaned thoroughly inside and outside before returning that it is free from hazardous material i e chemical biological toxic flamm...

Страница 17: ...ical fault p Premature wear p Connections plug connectors or cables loose p Wear parts p Operating elements e g switches push buttons p Breakage other damage p Electronic unit p Corrosion p Damage in...

Страница 18: ......

Страница 19: ......

Страница 20: ...180 497516 E Mail info lutz jesco nl Internet www lutz jesco nl USA Lutz JESCO America Corp 55 Bermar Park Rochester N Y 14624 USA Phone 1 585 426 0990 Fax 1 585 426 4025 E Mail mail jescoamerica com...

Отзывы: