IOM J500.32
Jerguson
®
LumaStar
™
2021.05
7
16633 Fol
tz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
www.clark-
reliance.com ● [email protected]
Routine Inspection
Keep window on the front of the light clean using a clean damp cloth. Avoid using chemical cleaners that may
damage the silicone seals. If cleaner is required, do not spray directly onto the light. Apply a small amount to the
rag and carefully wipe the glass only. Never use harsh abrasives, wire brushes, metal scrapers, or any material
that could scratch the window. The window may be cleaned while the unit is in operation.
The light may be removed while the unit is in operation during inspection or mainten
ance of the customer’s gage
glass. The Illuminator may also be disconnected from the power supply, if desired. Disconnect the cord at the
supplied screw connector adjacent to the power supply. The plant power going to the power supply does not
need to be disconnected.
CAUTION:
Incorrectly connecting the AC Input to the DC Output will caused permanent damage to the
power supply and possibly create the ignition of hazardous atmospheres.
WARNING:
Substitution of components may impair intrinsic safety.
Fuse
Power Indicating
LED
AC Neutral
Pre-wired DC
Output
AC Line
Associated Equipment [Exia]
Figure 1