©2004 Maytag Services

LP/Natural Gas Conversion 

JGD8348CDP, JGCP430ADP, JGCP6**ADP

Converting from Natural Gas to L.P. Gas 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to cooktop

 

before servicing, unless  

testing requires power. 
 

November 2004 

 

16023566 

©2004 Maytag Services 

5

Converting from Natural Gas to LP Gas 

Converting the Burner Orifice Spuds 

1.  Remove the grates and burner caps. 
2.  Remove burner base by removing 2 screws. 
3.  Trim a small piece of masking tape to the size of a 

dime and place it over the end of a 9/32" (or 7mm) 
nut driver. 

4.  Firmly press the nut driver over the orifice spud and 

loosen spud by turning counterclockwise. Carefully lift 
the nut driver out of the burner throat. Orifice spud 
should be captured in the recess.  Repeat this step 
for each burner. 

5.  Locate the LP orifice spud packet taped to the 

underside of the burner box. The spuds have small 
numbers stamped on the side. This number codes 
the orifice diameter and its correct burner location. 

NOTE:

  See chart and graphics below for location of 

components. 

6.  With the masking tape still in place in the recess of 

the nut driver, press an LP orifice spud into the 
recess so that it is snugly captured. 

7.  Carefully install the orifice spud in the appropriate 

burner throat by turning clockwise to tighten. 

8.  Tighten to a torque of orifice 15 to 20 inch-lbs. 
9.  Replace burner base.  Tighten screws to 25-30 inch-

lbs. 

10. Repeat steps 2 through 9 for each burner. 
11. Replace burner caps and grates. 
12. Save orifices removed from appliance for future use. 
 

Model JGD8348CDP 

Orifice Spuds 

LP

  

(burner) 

Orifice 

color 

(#)

 

 

Natural Gas

 

(burner) 

Orifice 

color 

(#)

 

9K (CF) 

Blue (#63)   

10K (CF) 

Brass (#53)

9K (RF) 

Blue (#63)   

10K (RF) 

Brass (#53)

6.5K (CR) 

Red (#68) 

 

10K (CR) 

Brass (#53)

6.5K (RR) 

Red (#68) 

 

10K (RR) 

Brass (#53)

7.5K (LF) 

Zinc (#66)   

8K (LF) 

Green (#55)

7.5K (LR) 

Zinc (#66)   

8K (LR) 

Green (#55)

 

Models JGCP430ADP, JGCP636ADP, JGCP648ADP 

Orifice Spuds 

LP

  

(burner) 

Orifice #  

 

Natural Gas

 

(burner) 

Orifice 

color 

9.1K (CF) 

#94 

 

9.2K (CF) 

Red 

15K (RF) 

#117 

 

17K (RF) 

Gold 

9.1K (RR) 

#94 

 

9.2K (RR) 

Red 

15K (LF) 

#117 

 

17K (LF) 

Gold 

4K (LR) 

#64 

 

5K (LR) 

Blue 

Converting Pressure Regulator for LP/Propane

 

1.  Remove pressure regulator cap using a wrench. 
2.  Apply sideward finger pressure to remove pin from 

cap. 

Apply sideways 

finger pressure

to remove pin 

from cap

 

3.  Apply downward finger pressure at the disc edges to 

place pin into the cap. 

LP

L.P.

Natural

NAT

 

4.  Place pressure regulator cap on pressure regulator 

and tighten. 

Low Flame Adjustment 

Properly adjusted burner flames are clean and blue with 
a distinct inner cone approximately ½ inch long. 

1.  Light burner and set control knob for low flame. 
2.  Remove control knob from valve stem. 
3.  Insert a slender thin bladed screwdriver into the 

recess at center of valve stem and engage blade with 
slot in adjusting screw. 

4.  Turn adjusting screw clockwise until tight. Do not over 

tighten. 

 

Clockwise to decrease 

 

Counterclockwise to increase 

5.  Repeat process for remaining burners. 

After adjusting the screw, the burner should produce a 
stable, steady blue flame of minimum size. The setting 
should be checked by turning the knob from high to low 
several times without extinguishing the flame. 
This operation will automatically provide the proper flame 
size at medium setting. 
After conversion steps have been completed, check the 
appearance of each burner flame at high and low 
settings. If the flames appear too large or small, review 
each step to verify it was completed correctly. 
 

Содержание PRO-STYLE JGD8348CDP

Страница 1: ...limited to the following JGD8348CDP JGC8430BDB Q S W JGC8645BDB Q S W JGCP430CDP JGCP636CDP JGCP648CDP Service This manual is to be used by qualified appliance technicians only Maytag does not assume...

Страница 2: ...WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate an authorized servicer please consult your telephone...

Страница 3: ...Module Removal Bottom Access 16 SparkModuleRemoval 16 SurfaceIgnitorRemoval 16 BurnerSwitchRemoval 16 ManifoldPipeRemoval 16 OrificeHolderRemoval 16 BurnerTubingRemoval 16 Disassembly Procedures for...

Страница 4: ...personal injury or death verify wiring is correct if components were replaced Verify proper and complete operation of unit after servicing WARNING This gas appliance contains or produces a chemical or...

Страница 5: ...ection and check for gas leaks Inform consumer of the condition of cooktop before leaving 7 Adhere to all local regulations and codes when performing service Before Installing Installing the gas cookt...

Страница 6: ...a properly certified flexible connector The pressure regulator supplied with cooktops have a 1 2 inch NPT female connection Check local codes before choosing a method WARNING Do not over tighten the f...

Страница 7: ...servicing regulator make certain it is set properly before completing service Gas Burner Orifices Universal orifices are used on most valves They must be adjusted or set for the type of gas being use...

Страница 8: ...her explanation Refer to the Technical Sheets or toll free technical support line to recieve technical assistance from authorized service technicians Cooking Nomenclature J G C 8 4 3 0 B D W Brand A A...

Страница 9: ...es receipt for future reference or in case warranty service is required To locate an authorized servicer For Jenn Air product call 1 800 688 1100 or visit the Web Site at www jennair com For product i...

Страница 10: ...ver screw is metal and not insulated and wall receptacle is grounded through the house wiring Consumer should have circuit checked by a qualified electrician to verify receptacle is properly grounded...

Страница 11: ...e spark module Electrode dirty Burner cap dirty Cracked or broken electrode electrode wire or electrode socket Verify voltage at wall outlet Check wiring against appropriate wiring diagram Verify all...

Страница 12: ...sure Natural gas pressure should be 5 WCP and LP gas pressure should be 10 WCP Check gas valve for continuity Verify all connections are clean and tight replace broken wire Fan motor does not operate...

Страница 13: ...ITE position 120 VAC Continuity in LITE position Dreefs spark switch JGD8348CDP Test for voltage at terminals Disconnect wiring and check for continuity in LITE position 120 VAC Continuity in LITE pos...

Страница 14: ...ontinuity from ignitor to chassis Pressure regulator All Verify gas pressure W C P If on LP service verify proper gas supply conversion 5 Natural 10 LP propane 270 Switch JGCP430ADP JGCP636ADP JGCP648...

Страница 15: ...check for continuity in LITE position 120 VAC Continuity in LITE position Spark switch JGC8430BD Test for voltage at terminals Disconnect wiring and check for continuity in LITE position 120 VAC Conti...

Страница 16: ...crews securing spark module to burner box 4 Disconnect and label wire leads from spark module NOTE Mark wires for exact replacement on module 5 Replace spark module and reverse procedure to reinstall...

Страница 17: ...ng unless testing requires power JGC8430BD JGC8645BDS BODY breakdown Burner Base Burner Caps Main Top Knobs Venturi Igniter Grates JGC8430BD JGC8645BDS BURNER BOX breakdown Burner Box Regulator Spark...

Страница 18: ...ain Top Removal procedure 2 Slide burner switch up and off burner valve stem 3 Disconnect and label wires from spark module and incoming power supply 4 Replace burner switch and reverse procedure to r...

Страница 19: ...wer JGD8348CDP JGCP430ADP JGCP636ADP JGCP648ADP BODY breakdown JGD8348CDP JGCP430ADP JGCP636ADP JGCP648ADP BURNER BOX breakdown Grates Air Grill Top Snap Switch Rotary Switch Grill Pans Pan Seal Contr...

Страница 20: ...the filter clears the air chamber 3 Reverse procedure to replace grease filter Blower Removal 1 Shut off gas supply and disconnect electricity to unit 2 Gain access to blower motor assembly located u...

Страница 21: ...2004 Maytag Services 16023565 A 1 Appendix A...

Страница 22: ...t alteration service maintenance or use of appliance can result in serious injury or property damage Leave these instructions with the appliance Retain these instructions for future reference 85 This...

Страница 23: ...2004 Maytag Services 16023565 A 3 Installation Instructions JGCP430ADP JGCP636ADP JGCP648ADP 85 85 35 1 16 89 06 cm 36 1 16 91 6 cm 30 76 20 cm 28 15 16 72 34 cm...

Страница 24: ...installed near a side wall must allow a minimum clearance of 8 20 32 cm Access must be provided to remove and empty grease container SELECT APPROPRIATE DUCT CUTOUT SEE DUCTING INSTALLATION INSTRUCTION...

Страница 25: ...2004 Maytag Services 16023565 A 5 Installation Instructions Ducting Instructions JGD8348CDP...

Страница 26: ...A 6 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP...

Страница 27: ...2004 Maytag Services 16023565 A 7 Installation Instructions Ducting Instructions JGD8348CDP...

Страница 28: ...A 8 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP...

Страница 29: ...ate on underside of burner box for this information Do not attempt to convert this appliance for use with a gas other than the type specified 8101P643 60 05 04 00 CUTOUT DIMENSIONS ARE CRITICAL 30 MOD...

Страница 30: ...o not attempt to convert this appliance for use with a gas other than the type specified 8101P644 60 05 04 00 45 MODEL INSTALLATION MANUAL SEALED GAS COOKTOPS JGC8645 403 WEST FOURTH STREET NORTH NEWT...

Страница 31: ...2004 Maytag Services 16023565 B 1 Appendix B...

Страница 32: ...the cooktop NEVER touch cooktop until it has cooled Expect some parts of the cooktop especially around the burners to become warm or hot during cooking Use potholders to protect hands Operating Durin...

Страница 33: ...600 BTUs on LOW This burner is designed for cooking delicate items 2 Left front burner 17 000 BTUs This burner may be used to quickly bring water to a boil for large quantity cooking 3 Center rear bur...

Страница 34: ...f the surface burner does not light check if ignitor is broken soiled or wet If clogged clean the small port beneath the ignitor using straight pin SURFACE CONTROL KNOBS Use to turn on the surface bur...

Страница 35: ...e pan To prevent the cooktop from discol oring or staining Clean cooktop after each use Wipe acidic or sugary spills as soon as the cooktop has cooled as these spills may discolor the porcelain SEALED...

Страница 36: ...affecting heat settings refer to Cooking Made Simple booklet SETTINGS USES Use Hi to bring liquid to a boil or reach pressure in a pressure cooker Always reduce setting to a lower heat when liquids be...

Страница 37: ...be used to quickly bring water to a boil and for large quantity cooking Simmer Burners These burners are located in the left front position and or the right rear position The simmer burner offers a lo...

Страница 38: ...urner will light All ignitors will spark when any surface burner knob is turned on However only the selected burner will light Operating During a Power Failure 1 Hold a lighted match to the desired su...

Страница 39: ...cooking Simmer Burners 850 BTUs These burners are located in the center positions The simmer burners offer a lower BTU flame for delicate sauces or melting chocolate BTU ratings will vary when using...

Страница 40: ...brushes or abrasive scour ing pads or other scrubbers intended to clean outdoor charcoal grills These will re move the finish as well as scratch the grates Do not clean in self cleaning oven or use o...

Страница 41: ...2004 Maytag Services 16023565 C 1 Appendix C...

Страница 42: ...ifice color Natural Gas burner Orifice color 9K CF Blue 63 10K CF Brass 53 9K RF Blue 63 10K RF Brass 53 6 5K CR Red 68 10K CR Brass 53 6 5K RR Red 68 10K RR Brass 53 7 5K LF Zinc 66 8K LF Green 55 7...

Страница 43: ...future use Model JGC8645BDS Orifice Spuds Natural Gas burner Orifice color or LP burner Orifice 6 5K CF Silver 5K CF 70 15K RF 49 8 5K RF 65 6 5K CR Silver 5K CR 70 9 1K RR Green 5 5K RR 69 9 1K LF G...

Отзывы: