5
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■
Level
■
Drill with 1¼" (3.0 cm) and
³⁄₁₆
" (5.0 mm) drill bits
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
T20
®†
Torx
®
bit or driver
Parts needed
For hard wire installations, you will also need:
■
Home power supply cable
■
½" (12.7 mm) UL listed or CSA approved strain relief
For vented installations, you will also need:
■
1 wall or roof cap
■
Metal vent system
For non-vented (recirculating) installations, you will also
need:
■
Recirculation Kit Part Number W10646866 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.
■
Charcoal Filter Kit Part Number W10272069. See “Assistance
or Service” section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
■
Hood canopy assembly with ventilator and lights installed
■
Vent mounting boss (attached to hood canopy assembly)
■
Damper
■
3 - 3.5 x 9.5 mm screws damper to mounting boss
■
Metal grease filter installed in hood canopy
■
Chimney cover support bracket
■
2-piece chimney cover
■
2 - 8 x 80 mm hanger bolts (T20
®
TORX
®
drive)
■
2 - 8 mm nuts
■
2 - flat washers
■
2 - 5 x 40 mm T20
®
Torx
®
drive screws for chimney bracket
mounting.
■
2 - 5 mm wall anchors
■
½" (13 mm) special nut tightening tool
■
2 - Plastic spacers for lower chimney
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
The canopy hood mounting location must be capable of
supporting 100 lbs (45.4 kg).
This range hood is recommended for use with cooktops with a
maximum total rating of 78,000 Btus or less.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see “For non-
vented (recirculating) installation only” in the “Connect Vent
System” section. Recirculation Kit Part Number W10646866 and
Charcoal Filter Kit Part Number W10272069 are available from
your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
†®T20 and TORX are registered trademarks of Acument Intellectual Properties, LLC.
A. 12
³⁄₈
" (31.4 cm)
B. 13
¹⁄₈
" (33.4 cm)
C. 36" (91.4 cm)
D. 19¼" (48.8 cm)
E. 1
⁵⁄₈
" (4.2 cm)
F. 25
⁹⁄₁₆
" (65.0 cm)
G. 33
¹⁄₈
" (84.1 cm) min.
54¾" (139.1 cm) max.