6. Run the home power supply cable through the strain relief, 

into the terminal box.

7. Loosen the screw labeled “L” on the terminal block and 

connect black wire C. Retighten the screw.

8. Loosen the screw labeled “N” on the terminal block and 

connect white wire D. Retighten the screw.

9. Loosen the screw labeled with the “Ground Symbol” on the 

terminal block and connect green (or bare) ground wire E. 
Tighten the screw.

10. Tighten the strain relief screws.
11. Reinstall the terminal box cover.
12. Reconnect power.

Install Chimney Covers

1. On the upper chimney cover, bend out tabs (2) approximately 

¹⁄₈

" (3 mm).

2. Slide rear flanges of upper chimney cover between catch 

tabs on chimney cover mounting bracket and lock bent-out 
tabs into slots in the back plate of the chimney cover 
mounting bracket.
NOTE: Once the upper chimney cover tabs are locked into 
the chimney cover mounting bracket, the upper chimney 
cover will be hard to remove. If removal is required, place a 
thin blade behind the top corner of the upper chimney cover 
and the chimney cover mounting bracket to push in the catch 
tabs on both sides, and pull the rear side flange out of the 
chimney cover mounting bracket.

3. Attach the (2) plastic spacers (F), one on each side at the 

bottom of the blower module.

4. Widen the lower chimney cover and slide it over the upper 

chimney cover and blower module. The lower chimney cover 
must rest on the top of the hood.

A. Home power supply cable
B. UL listed or CSA approved strain relief

C. Location “L” (black wire)
D. Location “N” (white wire)

E. Location ground symbol (green or bare ground wire)

D

A

B

C

E

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire 
in terminal box.

Failure to do so can result in death or electrical shock.

A. Ceiling
B. Chimney cover mounting bracket

C. Upper chimney cover - rear flanges
D. Upper chimney cover

E. Lower chimney cover

F. Plastic spacers (2)

¹⁄₈

"

(3 mm)

B

A

D

E

C

F

Содержание JXW8936DS

Страница 1: ...ns d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 JENNAIR 1 800 536 6247 ou visitez notre site web www jennair ca Table of Con...

Страница 2: ...the U S A 18 Accessories 18 In Canada 18 WARRANTY 19 TABLE DES MATI RES S CURIT DE LA HOTTE DE CUISINI RE 20 EXIGENCES D INSTALLATION 22 Outils et pi ces 22 Exigences d emplacement 22 Exigences conce...

Страница 3: ...is manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety mes...

Страница 4: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Страница 5: ...nician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the...

Страница 6: ...ap has a damper do not use the damper supplied with the range hood Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations A...

Страница 7: ...adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes an...

Страница 8: ...serial rating plate The model serial plate is located behind the filter on the rear wall of the range hood Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 lat...

Страница 9: ...d Mounting Screws Installation 1 Determine and mark the centerline on the wall where the canopy hood will be installed 2 Select a mounting height between a minimum of 24 61 0 cm for an electric cookin...

Страница 10: ...ents section For Vented Installations Only Using a jigsaw or keyhole saw cut a 6 16 5 cm diameter hole in the wall or ceiling for the vent duct Install the vent duct system through the hole Seal all c...

Страница 11: ...f vent duct to the top of the range hood top plate 4 Check the mounting boss handle for alignment The mounting boss handle must align parallel with the front of the range If alignment is needed loosen...

Страница 12: ...Remove the terminal box cover 3 Disconnect grounded power cord wires from terminal block Loosen the screws labeled L N and Ground Symbol 4 Remove power cord strain relief from terminal box and remove...

Страница 13: ...g bracket the upper chimney cover will be hard to remove If removal is required place a thin blade behind the top corner of the upper chimney cover and the chimney cover mounting bracket to push in th...

Страница 14: ...y Auto Sense the Auto button light will turn On To set Auto Sense Press AUTO To Select Auto Sense Cooktop Type NOTE The range hood is factory set for the gas cooktop mode Press and hold AUTO for 5 sec...

Страница 15: ...oap filled scouring pads Always wipe dry to avoid water marks Cleaning Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge then rinse with cl...

Страница 16: ...ture of 210 F 100 C To Remove Charcoal Filters 1 Turn fan and lights off 2 Remove the metal grease filters See Metal Grease Filters section 3 Remove the upper and side lock springs 4 Clean or discard...

Страница 17: ...Red Blue Black Frequency Power Supply Wattage Rating 14 90 Ohm 9 92 Ohm 22 00 Ohm Amperage Motor Speed Resistance 18 40 Ohm 420 W Blue Gray 60 Hz Blue White Component Layout Description Num E M I Filt...

Страница 18: ...iances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Accessories Charcoal Filter Kit for non vented installations...

Страница 19: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Страница 20: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Страница 21: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Страница 22: ...d emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l installateur qu incombe la responsabilit...

Страница 23: ...nduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou en aluminium La longueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour des performances o...

Страница 24: ...vers un mur Un circuit d vacuation en conduit rond de 6 15 2 cm est n cessaire pour l installation non fourni La hotte comporte une ouverture de sortie de diam tre 6 15 2 cm Un raccord d adaptation de...

Страница 25: ...MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit tre aliment par un circuit de 120 VCA seulement 60 Hz 15 A prot g par fusible Pour cordon d alim...

Страница 26: ...i arri re de la hotte Le calibre des conducteurs doit satisfaire aux exigences de la plus r cente dition de la norme National Electrical Code ANSI NFPA 70 ou des normes CSA C22 1 94 Code canadien de l...

Страница 27: ...moteur de la hotte Installation des vis de montage de la hotte 1 D terminer et marquer la position de l axe central sur le mur o la hotte sera install e 2 S lectionner une hauteur de montage comprise...

Страница 28: ...se ou scie guichet d couper un trou de 6 16 5 cm de diam tre dans le mur ou le plafond pour le conduit d vacuation Installer le circuit d vacuation travers le trou Utiliser des brides de conduit pour...

Страница 29: ...ue sup rieure de la hotte 4 V rifier l alignement de la poign e du bossage de montage La poign e du bossage de montage doit tre align e parall lement l avant de la hotte Si un alignement s av re n ces...

Страница 30: ...reli e la terre situ e au dessus de la hotte Pour c ble rigide depuis le point de distribution du domicile 1 D connecter la source de courant lectrique 2 ter le couvercle du bo tier de connexion 3 D c...

Страница 31: ...de connexion 12 Reconnecter la source de courant lectrique Installer les cache conduits 1 Sur le cache conduit sup rieur tordre les 2 languettes vers l ext rieur d environ 3 mm A Cordon d alimentatio...

Страница 32: ...isation de la hotte REMARQUE Pour pouvoir tirer le plus grand parti de la nouvelle hotte de cuisini re lire la section Utilisation de la hotte UTILISATION DE LA HOTTE La hotte de cuisini re est con ue...

Страница 33: ...Pour d sactiver la fonction Auto Sense d tection automatique Si le t moin lumineux du bouton Auto est allum appuyer une fois sur AUTO pour d sactiver la fonction Auto Sense Le t moin lumineux du bouto...

Страница 34: ...Le filtre graisse m tallique se trouve derri re le panneau vitr central Le panneau est fix par des charni res sur le c t gauche et fix par aimantation sur le c t droit Pour acc der au filtre graisse s...

Страница 35: ...s filtres graisse m talliques Voir la section Filtres graisse m talliques 3 Retirer les ressorts lat raux et sup rieurs du syst me de verrouillage 4 Nettoyer ou jeter le filtre charbon R installation...

Страница 36: ...u Gris 60 Hz Bleu Blanc Disposition des composants Description N Filtre IEM Interface utilisateur Carte principale Commande d clairage Condensateur Lampe DEL Fusible N N N N 1 N N JA VE JA VE BL BL BL...

Страница 37: ...act ristiques et sp cifications de notre gamme compl te d appareils m nagers R f rences aux concessionnaires locaux Jenn Air Renseignements pour l installation Proc d s d utilisation et d entretien Ve...

Страница 38: ...utions de conservation etc 5 Conversion de votre produit du gaz naturel ou du gaz de p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilis...

Страница 39: ...39 Notes...

Страница 40: ...W10640311B 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 5 14 Printed in Germany Imprim en Allemagne...

Отзывы: