3. Install all burner caps and burner bases.

Burner installation:

To install the spreader (B), insert the electrode (C) into the 
spreader hole.

Install surface grates:

The surface grates are positioned correctly when the thick ribs 
form a frame around the outer edge and the thin ribs are located 
across the middle. All burners will be centered with the burner 
openings in the grates. See the following illustration.
NOTE: The end grates are different than the center grate. Do not 
use the end grate in the center grate position.

4. Plug into a grounded 3 prong outlet.

Complete Installation

Electronic Ignition System

Check Operation of Surface Burners

1. Push in and turn the surface burner control knobs to the “Hi” 

position. 

The surface burner flame should light within 4 seconds. The 
first time a surface burner is lit, it may take longer than 
4 seconds to light because of air in the gas line. 

2. Check the flame on “Hi” for a blue color. It should be clean 

and soft in character. No yellow tip, blowing or lifting of flame 
should occur. Occasional orange flashes are normal and 
reflect different elements in the air or gas.

3. Repeat for the “Lo” position.

4. Repeat for the “Sim” position.

5. After verifying the proper burner operation, turn the control 

knobs to “Off.”

If burners do not light properly:

Turn the surface burner control knob to the “Off” position. 

Check that the power supply cord is plugged in and the 
circuit breaker has not tripped or the fuse blown. 

Check that the gas shutoff valve is set to the “open” position. 

Check that the burner bases and caps are properly 
positioned on the burners.

Recheck the operation of the surface burners. If a burner does 
not light at this point, call 1-800-JENN-AIR.

Standard Burner

A. Cap
B. Spreader

C. Electrode

Dual Flame Burner

A. Cap
B. Spreader

C. Electrode

A. Thick ribs
B. Thin ribs

C. End grates
D. Center grate

A

B

C

A

B

C

A

A

B

A

C

C

A

D

B

A. Correct
B. Incorrect

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

A

B

B

Содержание JGC1536BS

Страница 1: ...on 17 SCH MA DE C BLAGE 18 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potenti...

Страница 2: ...er WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detect...

Страница 3: ...ening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be ava...

Страница 4: ...onal Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circ...

Страница 5: ...be minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit use a flexible stainless steel tubing gas connector des...

Страница 6: ...nless steel gas supply line can be assembled to the cooktop before or after the cooktop is installed See the Make Gas Connection section 1 Remove the foam strip from the hardware package Remove the ba...

Страница 7: ...use with LP gas to the larger thread ends of the flexible connector adapters see B and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the ga...

Страница 8: ...racter No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat for the Lo position 4 Repeat for the Sim po...

Страница 9: ...s pushed in and rotated from 0 to 210 counterclockwise from Off 120 VAC 60 Hz 1 Phase 15 Amp GND Power Cord Plug L1 GND N GN BK BK WH WH 1 WH 2 WH 3 WH 4 WH 5 Spark Modules BK Valve Switches RF L1 N N...

Страница 10: ...AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observ s un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un d c s Ne pas entrepos...

Страница 11: ...cher de l emplacement d installation de la table de cuisson doivent tre scell es Respecter les dimensions indiqu es pour les ouvertures d couper dans les meubles Ces dimensions constituent les valeurs...

Страница 12: ...i le placard comporte un tiroir on devra m nager un d gagement de 4 10 2 cm ou plus entre le plan de travail et le dessus du tiroir ou autre obstacle dans le placard inf rieur Il pourra tre n cessaire...

Страница 13: ...us r cente dition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent tre effectu s selon les instructions du fab...

Страница 14: ...e utilis La pression d alimentation du d tendeur doit tre comme suit pour un fonctionnement correct Gaz naturel Pression minimum 6 15 2 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau Gaz p...

Страница 15: ...cuisson avant de monter cette derni re dans le placard Voir la section Raccordement au gaz Table de cuisson sur four encastr IMPORTANT Ne pas utiliser de brides de fixation 1 Installer la table de cu...

Страница 16: ...de la configuration d installation Raccordement typique par raccord flexible 1 Appliquer un compos d tanch it des filetages r sistant au propane sur l extr mit filet e la plus grosse des adaptateurs d...

Страница 17: ...t tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 V rifier que la flamme est bleue la position Hi Elle doit tre propre et douce On ne doit pas observer de pointe ja...

Страница 18: ...ns le sens anti horaire entre 0 et 210 depuis la position d arr t Terre Ph1 Terre NEU VE N N BL BL 1 BL 2 BL 3 BL 4 BL 5 N AvD Ph1 Neu Neu ArD N N N C Neu Ph1 C ArG Neu Ph1 N N N N N N C AvG Neu Ph1 l...

Страница 19: ...19 Notes...

Страница 20: ...W10676381C 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 5 14 Printed in U S A Imprim aux U...

Отзывы: