Installation Clearances
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTE: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the burner box. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator and power cord.
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA
70 or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that
will not operate if plugged into an outlet that is not properly
polarized.
This cooktop is equipped with an electronic ignition system that
will not operate properly if plugged into a ground fault interrupt
circuit.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
■
A 120-volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range be provided.
■
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded
and polarized.
■
The wiring diagram is provided with this cooktop. See “Wiring
Diagram” section.
A. 18" (45.7 cm) minimum clearance upper cabinet to countertop
B. Cabinet
C. 36" (91.4 cm)
D. 13" (33 cm) maximum recommended upper cabinet depth
E. 6" (15.2 cm) minimum side wall clearance
F. 30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet (24"
[61 cm] minimum clearance if bottom of wood or metal cabinet
is covered by not less than
¹⁄₄
" [0.6 cm] flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum
or 0.020" [0.05 cm] copper)
G. 2
⁵⁄₁₆
" (5.9 cm) minimum distance to rear combustible surface
H. 2
⁵⁄₁₆
" (5.9 cm) minimum distance to front countertop edge
I. Cutout width - 29
³⁄₈
" (74.6 cm) on 30" (76.2 cm) models
Cutout width - 35
³⁄₈
" (89.9 cm) on 36" (91.4 cm) models
J. Cutout depth - 20
³⁄₈
" (51.8 cm)
B
A
D
E
C
F
G
H
I
J
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.