Illustration Component
Test
Procedure
Results
Top surface burner
6.5 K btu,
9.1 K btu
10.5 K btu
12 K btu
Model JDS8850A**
Verify gas is supplied .........................
Verify burner cap is positioned
correctly.
Check for obstructions in burner ports.
Top surface burner
cap
Model JDS8850A**
Verify cap is positioned correctly ........ Check for obstructions in burner ports.
L
A
B
A1
B1
N
Spark module 4 + 0
Model JDS8850A**
Test for voltage at terminals L and N..
Check polarity and ground..................
120 VAC (tolerance: 109 to 125 VAC)
See wiring diagram
Ignitor
Model JDS8850A**
Test for voltage at terminals ...............
Test for the amount of amperage in
the circuit ............................................
(Ignitor may glow but not have
sufficient amperage to open valve).
120 VAC.
3.2
−
3.6 Amps If not replace.
Burner valve, left,
360°
Model JDS9860A**
Verify gas is supplied.
Orifice adjusted for
Natural or LP.
Adjust set screw for simmer control....
To replace burner valve(s), complete
assembly must be replaced (manifold
and valves).
16,000 BTU per hour minimum.
See conversion section.
Burner valve,
left and right, 180°
Model JDS9860A**
Verify gas is supplied. ........................
Orifice adjusted for
Natural or LP
To replace burner valve(s), complete
assembly must be replaced (manifold
and valves).
Shut-off valve
Model JDS9860A**
Verify gas is turned on........................ Gas ON.... end slot is vertical.
Gas OFF .. end slot is horizontal.
Spark switch
Model JDS8850A**
Test for voltage at terminals ...............
Disconnect wiring and check for
continuity in LITE position...................
120 VAC
Continuity in LITE position.
Double valve switch
Model JDS9860A**
Test for voltage at terminals ...............
Disconnect wiring and check for
continuity in LITE position...................
120 VAC
Continuity in LITE position.
Snap switch
Model JDS9860A**
Test for voltage at terminals ...............
Disconnect wiring and check for
continuity in LITE position...................
120 VAC
Continuity in LITE position.
L
A
B
A1
B1
N
Spark module
4 + 0
Model JDS9860A**
Test for voltage at terminals
L and N...............................................
Check polarity and ground..................
120 VAC.
See wiring diagram.
Venturi, front
(short)
Model JDS9860A**
Nominal air shutter setting..................
Tolerance ...........................................
.375 3/8"
.030 1/32"
Содержание JDS8850AAB
Страница 29: ... 2005 Maytag Services 16026016 A 1 Appendix A ...
Страница 45: ... 2005 Maytag Services 16026016 B 1 Appendix B ...
Страница 56: ...B 12 16026016 2005 Maytag Services Care Information CLEAN PAD CARE C LEANING NOTES ...
Страница 59: ... 2005 Maytag Services 16026016 C 1 Appendix C ...