6
ELECTRICAL WIRING INFORMATION
This appliance is equipped with a grounded type power cord. A grounded
outlet must be provided. It is recommended, for convenience, the outlet be
located (with reference to figure 6) as in A or B, below:
A. If no other appliance is to be installed below this appliance: within either
the shaded area or the cross hatched area shown in figure 6.
B. If a Model W30XXX or W131 electric oven is to be installed below this
appliance, either:
1. within the cross hatched area of figure 6, or,
2. within an adjacent cabinet.
FIGURE 6
3
1/2
²
(8.89 cm) wide
slats when a wall
oven is installed
below 30
²
Model
Dimension A:
W30XXX: 5-1/2
²
(13.97 cm)
W131: 4
²
(10.16 cm)
If a wall oven is to be installed below this appliance and the counter unit’s
outlet is to be mounted within the cross hatched area of figure 6:
1. The cabinet’s lower front panel, below the oven, must be made
removable for access to the outlet.
2. A clearance hole for the power cord’s plug (1-1/4
²
(3.18 cm) dia is
recommended) must be provided through the oven’s floor support shelf
and, if necessary, through the slats supporting the shelf. The clearance
hole should be located as near as practical to the rear of the shelf and
(if the oven is model W30XXX) as near as practical to the left rear corner.
3. When model W30XXX is mounted below thisappliance, andif thepower
outlet for this appliance is to be located in the cross hatched area of
figure 6, it is recommended the power cord be routed through the
external vertical clearance channel at the left rear of the oven. The
channel’s cross section is approximately 4.2
²
x 2.25
²
(10.7 x 5.7 cm),
extending the full height of the oven. (Model W131 provides a similar,
but larger, vertical channel near the center of the main back of the oven.)
If the outlet is to be mounted in either a left or right adjacent cabinet, a
clearance hole, as described above, must be provided in the dividing wall
between the cabinets. Figure 4; page 3, illustrates a typical (left side)
dividing wall. The clearance hole (not shown in figure 4) can be located as
is convenient in this left wall or in the corresponding right wall.
In planning any installation, note that the free length of this appliance’s
power cord, extending beyond a point 3-3/4
²
(9.53 cm) left of the nominal
center of the rear wall of the burner box, when viewed from the front of the
unit, is approximately 46
²
(117 cm).
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG
GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG FROM THIS PLUG.
WARNING
THIS APPLIANCE MUST BE DISCONNECTED FROM ITS
ELECTRICAL SUPPLY AT THE WALL RECEPTACLE BEFORE
SERVICING THE APPLIANCE.