Cabinet Dimensions

*NOTE: Grills installed near a side wall must allow a minimum 

clearance of 6" (15.2 cm) between cooktop and sidewall for 
maximum performance. Minimum clearance of 1" (2.5 cm) is 
required to sidewalls and ¾" (1.9 cm) to rear wall.

NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.

Where possible, a 6" (15.2 cm) clearance is recommended for 
motor blower service. A minimum clearance of 1" (2.5 cm) is 
recommended to the sidewalls and a 

³⁄₄

" (1.9 cm) clearance is 

recommended to the rear wall.

A minimum clearance of 

2

" (5.1 cm) is recommended 

between the motor/blower and cabinet for proper cooling.

A minimum clearance of 

6¹⁄₄

" (15.9 cm) is recommended for 

removal of the grease container(s). Installed dimension for the 
grease containers is 5

¹⁄₂

" (14.0 cm). 

For grills installed near a sidewall, a minimum clearance of 

6

" (15.2 cm) is recommended between the cooktop and 

sidewall for maximum performance.

Cutout Dimensions

Venting Requirements

Do not terminate the vent system in an attic or other enclosed 
area.

Use a Jenn-Air

®

 vent cap.

Vent system must terminate to the outside.

Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is 
recommended. For best performance, do not use plastic or 
metal foil vent.

Before making cutouts, make sure there is proper clearance 
within the wall or floor for the exhaust vent.

Do not cut a joist or stud unless absolutely necessary. If a 
joist or stud must be cut, then a supporting frame must be 
constructed.

The size of the vent should be uniform.

The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.

A. 24" (61.0 cm) on 20" (50.8 cm) single cartridge models

30" (76.2 cm) on 30" (76.2 cm) double cartridge models
43" (109.2 cm) on 43" (109.2 cm) triple cartridge models

B. Combustible area above countertop (shown by dashed box above)

C. 30" (76.2 cm) minimum clearance between top of cooktop platform 

and bottom of uncovered wood or metal cabinet (24" [61 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than 

¹⁄₄

" [0.6 cm] flame retardant millboard covered with 

not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)

D. 13" (33 cm) recommended upper cabinet depth

E. 2

¹⁄₈

" (5.4 cm) min.

F. 20

⁹⁄₁₆

" (58.2 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 

within minimum horizontal clearances to cooktop

H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 

countertop

I. Junction box or outlet; 10" (25.4 cm) from right-hand side of 

cabinet

J. 18

¹¹⁄₁₆

" (47.5 cm) on 20" (50.8 cm) single cartridge models

30

⁷⁄₁₆

" (77.3 cm) on 30" (76.2 cm) double cartridge models

41

³¹⁄₃₂

" (106.6 cm) on 43" (109.2 cm) triple cartridge models

K. Side clearance - See *NOTE.

L. 2" (5.1 cm) minimum clearance between back wall and countertop 

cutout

D

A

E

I

J

K

G

H

L

C

F

B

A. 18

¹¹⁄₁₆

± 

¹⁄₁₆

" (47.5 cm ± 0.2 cm) on 20" (50.8 cm) single cartridge 

models
30

⁷⁄₁₆

± 

¹⁄₁₆

" (77.3 cm ± 0.2 cm) on 30" (76.2 cm) double cartridge 

models
41

³¹⁄₃₂

± 

¹⁄₁₆

" (106.6 cm ± 0.2 cm) on 43" (109.2 cm) triple 

cartridge models

B. 20

⁹⁄₁₆

± 

¹⁄₁₆

" (52.2 cm ± 0.2 cm) maximum on all models

C. 6

⁵⁄₁₆

" (16.0 cm) on 20" (50.8 cm) single cartridge models

17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models
17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge models

D. 14

⁷⁄₁₆

" (36.7 cm) on all models

E. 2

¹⁄₈

" (5.4 cm) minimum space to front edge of cooktop

F. Minimum cabinet width:

21" (53.3 cm) on 20" (50.8 cm) single cartridge models
33" (83.8 cm) on 30" (76.2 cm) double cartridge models
43" (109.2 cm) on 43" (109.2 cm) triple cartridge models

G. Floor exhaust option

H. 6

¹⁄₈

" (15.6 cm) for 6" vent system

I. 6

⁵⁄₁₆

" (16.0 cm) on 20" (50.8 cm) single cartridge models

17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models
17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge models

J. 8" (20.3 cm) from center of the vent hole in the cabinet to the top 

surface of the countertop, on all models

K. Wall exhaust option

A

B

C

D

E

G

H

I

J

K

F

Содержание 20" (50.8 CM)

Страница 1: ...cuisson 20 Rotation du ventilateur facultative 20 Installation de la table de cuisson 21 Raccordement lectrique 22 Achever l installation 23 You can be killed or seriously injured if you don t immedi...

Страница 2: ...alling a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Use the countertop opening dimensions that are given with these Installation Instructions Given...

Страница 3: ...imum performance Minimum clearance of 1 2 5 cm is required to sidewalls and 1 9 cm to rear wall A minimum clearance of 6 15 9 cm is recommended for removal of the grease containers Installed dimension...

Страница 4: ...s 43 109 2 cm on 43 109 2 cm triple cartridge models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovere...

Страница 5: ...an cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using 6 15 2 cm or 3 x 10 8 3 x 25...

Страница 6: ...7 cm to 15 2 cm transition F 6 15 2 cm round metal duct G 6 15 2 cm round PVC coupling H Concrete slab I 6 15 2 cm round PVC sewer pipe J 6 15 2 cm round 90 PVC sewer pipe elbow K Tightly pack gravel...

Страница 7: ...ts If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes Check wit...

Страница 8: ...local codes and industry accepted wiring practices INSTALLATION INSTRUCTIONS PrepareCooktop Decide on the final location for the cooktop 1 Open product as instructed on product packaging 2 Remove ship...

Страница 9: ...tire cooktop up from the cutout to avoid scratching the countertop 2 Connect blower exhaust scroll to ducting 3 Use vent clamps to secure the ducting to the blower exhaust scroll 4 Use the hold down s...

Страница 10: ...TANT Use the 3 wire cable from power supply where local codes permit connecting the frame ground conductor to the neutral white junction box wire 1 Disconnect power 2 Remove wiring box cover from the...

Страница 11: ...on of the Use and Care Guide 5 Read Cooktop Use in the cooktop Use and Care Guide 6 Reconnect power 7 Use the Flow Tester Card provided with your cooktop to check the airflow see card for step by step...

Страница 12: ...ce doit tre vit Si des placards de rangement sont envisag s le risque peut tre r duit par l installation d une hotte de cuisine d passant le bas des placards d au moins 5 12 7 cm horizontalement Utili...

Страница 13: ...ntre la table de cuisson et la paroi lat rale pour une performance maximale Un d gagement minimum de 1 2 5 cm avec les parois lat rales et de 1 9 cm avec le mur arri re Un d gagement minimal de 6 15 9...

Страница 14: ...ue de 20 50 8 cm 30 76 2 cm sur les mod les module amovible double de 30 76 2 cm 43 109 2 cm sur les mod les module amovible triple de 43 109 2 cm B Zone de mati re combustible au dessus du plan de tr...

Страница 15: ...rale pour un rendement maximal Dimensions de l ouverture d couper A 18 47 5cm 0 2 cm sur les mod les module amovible unique de 20 50 8 cm 30 77 3 cm 0 2 cm sur les mod les module amovible unique de 30...

Страница 16: ...duit une paisseur de 30 pour l acier galvanis ou de 26 pour l aluminium si c est permis par les codes locaux Cette information est bas e sur l information dans la Section des Codes R sidentiels Inter...

Страница 17: ...le mur A B A B A B A B 3 x 10 8 3 x 25 4 cm A Bouche de d charge murale B 12 30 5 cm minimum C Dalle de b ton D Conduit PVC dia 6 15 2 cm pour gout E Raccord de transition 5 6 12 7 cm 15 2 cm F Condui...

Страница 18: ...moteur du ventilateur la volute d vacuation du ventilateur 3 Retirer le moteur du ventilateur B de sa volute d vacuation E 4 Dans l ouverture de la volute d vacuation du ventilateur retirer avec pr ca...

Страница 19: ...109 2 cm Le circuit doit tre prot g par fusible chaque extr mit du circuit La table de cuisson doit tre connect e directement au bo tier de connexion par l interm diaire du conduit m tallique flexibl...

Страница 20: ...Au d ballage la spirale d chappement du ventilateur est orient e vers l arri re du placard pour une vacuation travers une paroi ext rieure Pour tourner le ventilateur 1 Rep rer les 4 bouchons en plast...

Страница 21: ...du ventilateur aux conduits 3 Utiliser des brides de conduit pour fixer les conduits la volute d vacuation du ventilateur 4 Utiliser les brides de fixation fournies dans le paquet de pi ces de quincai...

Страница 22: ...de la table de cuisson 4 Connecter le conducteur de terre vert ou nu du point de distribution du domicile au conducteur de terre vert ou nu dans le bo tier de connexion de la chambre de distribution a...

Страница 23: ...ation 1 V rifier que toutes les pi ces sont maintenant install es S il reste une pi ce passer en revue les diff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les...

Страница 24: ...its r serv s Registered Trademark Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e Marque de commerce de Jenn Air U S A Emploi sous licence par Maytag Limited...

Отзывы: