12
HOW TO….
REFER TO SCHEMATICS / DIAGRAMS IN THE APPENDIX FOR MORE DETAILS
How To Change A Heat Exchange:
1. Always try to change a
HEAT EXCHANGE
when it is cold as the exposed metal parts can be
VERY HOT
.
2.
DISCONNECT FROM MAINS SUPPLY.
3. Remove
TOP COVER.
4. Disconnect the
THERMOCOUPLE
from the
MAIN PCB.
5. Disconnect the
HEAT EXCHANGE POWER WIRES
from the terminals of the
PCB.
6. Remove the negative (
BLUE
) wire from the heater.
7. Undo the brass nut that connects the
BRASS ASSEMBLY
to the
HEAT EXCHANGE
and
disconnect the fluid line from the pump.
8. Undo the 4 screws that hold the
HEAT EXCHANGER
to the
CHASSIS.
9.
Withdraw the
NOZZLE
of the heater through the hole and remove the heat exchange from the
chassis
.
Refitting Your New Heater:
1. Replace heat exchange in chassis
NOZZLE FIRST
.
2. Screw the 4 screws back in through the bottom of the chassis
3. Replace the negative (
BLUE
) wire to the
HEAT EXCHANGER ELEMENT
.
4. Reconnect the
HEATER POWER
wires to the
TERMINALS
of the
PCB.
5. Using a
NEW OLIVE
refit the
COPPER FLUID LINE
to the
PUMP
.
6.
RECALIBRATE
the temperature of the unit. (
See Calibration Section
)