background image

USER MANUAL

JEFC025L08B Series

25L

 AIR  COMPRESSOR 

 2HP 

 8Bar 

 Direct Drive

www.jeffersontools.com

9

  OPERATION GUIDE 

 

WARNING: 

Take care when selecting tools for use with the compressor. Air tool manufacturers normally express the volume of air required to 

operate a tool in cubic feet per minute (cfm). This refers to free air delivered by the compressor (‘air out’) which varies according to the pressure 
setting. Do not confuse this with the compressor displacement which is the air taken in by the compressor (‘air in’). ‘Air out’ is always less than ‘air 
in’ due to losses within the compressor.

Starting The Compressor: 

Before starting the compressor check that the Pressure / 

ON/OFF

 switch is in the “

OFF

” position, the regulator tap is closed, the output gauge 

must read Zero ‘

0

’ bar.

Plug mains lead into mains supply and start the compressor by moving the main switch to the ‘

ON

’ position. 

The pressure switch automatically controls the power to the motor. It also allows for manual operation via the Push/Pull - On/Off switch on top of 
the pressure switch. 

Use the Pressure Switch controls to turn the compressor "

ON/OFF

". The Pressure Switch is a push/pull switch type. To turn the compressor ‘

ON

’ 

pull the switch knob upwards. To turn the compressor '

OFF

’ push the knob downwards.

The pressure switch is factory set to turn the compressor on when the tank pressure drops below 85 psi and turn itself off again when the tank is 
full.

Note:

 

When starting the compressor for the first time, leave it running with no air tools connected to the air outlet. Make sure that pressure in 

the tank rises and that the compressor stops automatically when the maximum pressure is reached  - this information is indicated on the data 
specification plate and shown on the pressure gauge. 

The compressor will now operate automatically. The pressure switch stops the motor when the maximum tank pressure is reached and restarts it 
when the pressure falls below the minimum threshold - approx. 2 bar (29psi) less than the maximum pressure.

Stopping The Compressor: 

Stop the compressor by moving the main switch to the ‘OFF ‘position. The compressed air inside the compressor head will flow out, making the 
restart easier and preventing the motor from being damaged. 

DO NOT, other than in an emergency, stop the compressor by switching off the mains socket, or by pulling the plug out, as the pressure relief will 
not then operate and motor damage may result upon restart.

When the compressor runs correctly and is stopped correctly there will be:

(1)

 a whistle of compressed air when the motor stops,

(2)

 a protracted whistle (about 20-25 seconds) when the compressor starts with no pressure in the tank.

Regulating The Pressure: 

The output pressure is regulated by the pressure regulator. Lift and turn the knob clockwise to increase pressure and anticlockwise to reduce 
it - push knob down to lock in required position. To determine the correct working pressure for any piece of equipment check the corresponding 
manual for your tool. 

When the compressor is not being used set the regulated pressure to zero so as to avoid damaging the pressure regulator.

WARNING: 

If the motor does not cut in and out, but runs continuously when using an air appliance, the capacity of the compressor may be too 

small for the equipment or tool. 

The gauge indicates the pressure inside the main tank, NOT the pressure supplied to the air equipment. Should the pressure in the main tank 
exceed the pre-set switch maximum, a safety valve will activate. 

For this reason DO NOT tamper with, or adjust, the switch or safety valve.

When the compressor is not in use, it should be switched off, disconnected from the mains supply and the air drained from the tank.

Содержание JEFC025L08B Series

Страница 1: ...User Manual v 1 2 JEFC025L08B Series...

Страница 2: ...USER MANUAL JEFC025L08B Series 25L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 2...

Страница 3: ...information to ensure its correct and safe use We recommend that this manual is read before any operation or before performing any kind of adjustment to the product and prior to any maintenance tasks...

Страница 4: ...sure 8bar 116psi 8bar 116psi Wheel Diameter 135mm 135mm Lubrication Semi Synthetic SAE30 Optional 15W 40 220 cc Semi Synthetic SAE30 Optional 15W 40 220 cc Weight NW 27 5kg GW 29kg NW 27 5kg GW 29kg E...

Страница 5: ...dot indicates the low mark Important Always ensure that the oil level is correct before operating the compressor Ensure working environment is suitable for use This compressor must be used on a flat...

Страница 6: ...t all portable equipment must be inspected regularly and tested to ensure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portab...

Страница 7: ...ir vent must be kept clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or...

Страница 8: ...in a confined area with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nyl...

Страница 9: ...sure gauge The compressor will now operate automatically The pressure switch stops the motor when the maximum tank pressure is reached and restarts it when the pressure falls below the minimum thresho...

Страница 10: ...d service agent There is a leak from the base of the pressure switch when the compressor is stopped The Non return valve from the tank is leaking Disassemble and clean if necessary replace valve inser...

Страница 11: ...onnected from the power source Allow the compressor pump and other parts to cool off if changing oil after use Ensure compressor is on a flat and level surface Remove fill cap plug and place collectio...

Страница 12: ...USER MANUAL JEFC025L08B Series 25L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 12 PARTS DIAGRAM MAIN ASSEMBLY...

Страница 13: ...1 Ball Balve 9 2 Washer 10 2 Wheel 11 2 Axle 12 2 Hex Nut 13 2 Washer Spring 14 2 Plate Washer 15 6 Bolt Hex 16 4 Plate Washer 17 1 Check Valve 18 2 Sleeve 19 1 Aluminium Tube 20 1 Bushing Nylon Tube...

Страница 14: ...USER MANUAL JEFC025L08B Series 25L AIR COMPRESSOR 2HP 8Bar Direct Drive www jeffersontools com 14 PARTS DIAGRAM PUMP...

Страница 15: ...1 Rotor Ass y 41 2 Stud Bolt 12 1 Oil Seal 42 2 Hex Nut 13 1 Head Bolt 43 1 Gasket Valve 14 1 Bearing 6204 44 2 Valve Plate 15 1 Hex Nut 45 1 Gasket Valve 16 1 Washer Spring 46 2 Blade Valve 17 1 Cran...

Страница 16: ...uropean Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European...

Страница 17: ...ka Cesta 56 821 01 Bratislava Country Slovakia 1354 2011 65 EU as amended RoHS Directive Intertek Testing Services Shanghai Block B Jinling Business Square No 801 YiS han Road Shanghai China 200233 00...

Страница 18: ...as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect wil...

Страница 19: ...and in need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructe...

Страница 20: ...rk Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating...

Отзывы: