- 47 -
7.2.4 Battery charger
General points
- The battery charger runs on AC power.
- A breaker protects the electrical circuit.
- The battery charger charges all of the batteries onboard, while keeping the service battery
bank isolated from the engine's battery bank.
- Within its power limits, the DC equipment can be supplied directly.
Operation
- The charger runs fully automatically. It can remain permanently connected to the batteries
and does not need to be disconnected when starting the engine.
- In some electrical circuits, there may be battery chargers coupled in parallel.
Maintenance
- Before doing any maintenance, cut the AC supply.
- Regularly vacuum out any dust particles which may accumulate in the charger. An annual
check of the tightness of the nuts and bolts is necessary to ensure the correct operation of the
charger.
Capacity: 12 V - 25A
IT IS IMPERATIVE TO DISCONNECT THE BATTERY CHARGER BEFORE
DISCONNECTING THE BATTERY TERMINALS FOR MAINTENANCE.
7
D
C
I
N
S
T
A
L
L
A
T
IO
N
Содержание MERRY FISHER 695 MARLIN
Страница 1: ...MERRY FISHER 695 MARLIN OWNER S MANUAL 981522 Index C...
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 18: ......
Страница 24: ...24 Diagram of the layout Navigation lights...
Страница 34: ...34 Diagram of the layout Drying out the bilge...
Страница 36: ......
Страница 48: ...48 Layout diagram DC circuit...
Страница 50: ...50 7 2 5 Layout of the wiring looms in the hull DC circuit...
Страница 60: ......
Страница 62: ...62 10 3 FILLING CIRCUIT FRESH WATER DISTRIBUTION...
Страница 76: ......
Страница 88: ......
Страница 102: ...102 14 4 SALOON TABLE...
Страница 105: ...105 15 3 UPPER LIMIT OF ANTIFOUL Note Measurements are expressed in mm 15 HANDLING TRANSPORT...
Страница 110: ......
Страница 114: ...114...
Страница 115: ...115 17 APPENDIXES...
Страница 116: ......