- 123 -
197895 RCD-2
Index B
L
OCKING
METHOD
It is possible to lock the control buttons to prevent settings from being changed accidentally:
Press these three buttons simultaneously: MODE, UP (arrow pointing up), FAN.
LC appears on the screen, which signifies "LOCK".
To unlock and resume use of the buttons, press the same three buttons simultaneously:
MODE, UP (arrow pointing up), FAN.
UL appears on the screen, which signifies "UNLOCK".
S
CREEN
LIGHTING
If the control box is switched off by a fault (in the cabins for example), touching any button
automatically and instantly lights the screen up blue.
To alter the light intensity of the screen, press these two buttons simultaneously: MODE, UP
(arrow pointing up) until the required intensity is reached.
It is possible to programme whether or not the controls are illuminated by default: In this case
the ON mode must be selected for permanently illuminated controls or the SLEEP mode for
permanently unilluminated controls.
Procedure:
- Simultaneously press these two buttons: MODE and DOWN (arrow pointing down).
- Select n°18 on the menu using the arrows, then confirm by pressing MODE.
- With the arrows select either ON for illumination by default or SL (SLEEP) to turn the box off.
- Press FAN 2 times to confirm the selection.
NOTES
- When the system is in dehumidifying mode, the system's safety devices remain active: if
there is an interruption in the flow of seawater or a drop in AC voltage, the system
automatically stops.
- In cooling mode, the system works efficiently when the seawater temperature is below
30°C.
- In heating mode, the system works efficiently when the seawater temperature is above
13°C.
- It is important to switch the system to HEATING mode at least once a month to prevent
the changeover cock from becoming stuck in the COOLING mode.
11
ONBOARD COMFORT
Содержание LEADER 33 OUTBOARD
Страница 1: ...197895 RCD 2 Index B LEADER 33 OUTBOARD VERSION OWNER S MANUAL...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 52: ......
Страница 61: ...61 197895 RCD 2 Index B Diagram of layout 7 ELECTRICAL SYSTEM...
Страница 62: ...62 197895 RCD 2 Index B 7 2 6 Layout of hull wiring looms DC circuit...
Страница 63: ...63 197895 RCD 2 Index B 7 2 7 Layout of deck wiring looms DC circuit 7 ELECTRICAL SYSTEM...
Страница 64: ...64 197895 RCD 2 Index B 7 2 8 Layout of wiring looms in the deck backing moulding DC circuit...
Страница 65: ...65 197895 RCD 2 Index B 7 2 9 Sportop wiring harness plan DC circuit 7 ELECTRICAL SYSTEM...
Страница 88: ...88 197895 RCD 2 Index B...
Страница 90: ...90 197895 RCD 2 Index B...
Страница 92: ...92 197895 RCD 2 Index B Brazil Version 220V 60Hz...
Страница 96: ...96 197895 RCD 2 Index B 7 4 6 Layout of hull wiring looms AC circuit...
Страница 97: ...97 197895 RCD 2 Index B 7 4 7 Layout of deck wiring looms AC circuit 7 ELECTRICAL SYSTEM...
Страница 112: ...112 197895 RCD 2 Index B Fridge Location Galley Cockpit fridge...
Страница 118: ...118 197895 RCD 2 Index B Layout of components Compressors 1 Seawater pump 2 Seawater filter 3 Seawater intake...
Страница 121: ...121 197895 RCD 2 Index B Air conditioning controls Please refer to the key on the following page 11 ONBOARD COMFORT...
Страница 132: ......
Страница 136: ...136 197895 RCD 2 Index B 12 4 FRESH WATER DISTRIBUTION SYSTEM...
Страница 154: ......
Страница 170: ......
Страница 182: ......
Страница 188: ......
Страница 196: ......