Chapter 4
E1 Testing
Testing MFC-R2 Signaling
SmartClass E1 Tester User’s Guide
47
5
From the Configuration menu, select
Simulate Settings
, and then specify
the values as described below:
Clock Source
(selectable only in Simulate
test mode)
Select one of the following:
–
Internal
–
Rx1
–
Rx2
–
Ext. BNC
NOTE:
If timing is lost, the SmartClass reverts
to internal timing.
Framing
Select one of the following:
–
PCM30C
–
PCM30
MF Channel
Select the MF channel or channels.
– To turn on the selected channels, use the
arrow keys to point at the channels/
timeslots you want to turn on, and then
press the
#
key to select it.
– If in Monitor/Bridge mode, you can select
multiple channels.
– If in Simulate mode, select only one chan-
nel.
When you have finished selecting channels,
press
OK
.
Idle Code
(selectable only in Simulate
test mode)
Enter an 8-bit binary string
Setting
Parameter
Sequence Generation
Select one of the following:
–
Express
–
Advanced
Direction
Select one of the following:
–
Forward
–
Backward
DID Number
(selectable only for Forward
Direction and Express
Sequence Generation)
Enter the Direct Inward Dial (DID) number.
This is the phone number to be called.
ANI Number
(selectable only for Forward
Direction and Express
Sequence Generation)
Enter the Automatic Number Identification
(ANI) number. This is the caller's number, typ-
ically the E1Tester’s own number.
Category
(selectable only for Forward
Direction and Express
Sequence Generation)
Select a category. This is the E1Tester’s own
category, from II-1 to II-15.
Number of DIDs
(selectable only for Back-
ward Direction and Express
Sequence Generation)
Specify the number of DIDs on the circuit.
Setting
Parameter
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......