Specify the test settings. The following table describes the settings.
Setting
Parameter
Test Mode
Select one of the following:
–
Terminate
– Monitor
–
Bridge (HI-Z)
AMS Jitter Mode
Select one of the following:
–
MTJ
- maximum tolerable jitter
–
FMTJ
- fast maximum tolerable jitter
–
JTF
- jitter transfer function
AMS Jitter Settings
Specify the following automated measure-
ment sequences (AMS) settings:
–
Settling Time
- The amount of time a
DUT is allowed to settle and adjust to a
change in the frequency or amplitude of a
received signal. The E1 Tester resumes
error measurement after the specified
time elapses.
–
Gate Time
- Time duration for error mea-
surement. During this period the error
source is accumulated if it is an error or
recorded if it is an alarm. (not selectable if
Jitter Mode is “JTF”.)
–
Sensor Threshold
- The number of
alarms or errors allowed by the MTJ/Fast
MTJ sensor that will result in a pass status
for a particular transmit amplitude and fre-
quency point. (not selectable if Jitter Mode
is “JTF”.)
–
Sensor
- The alarm or error source used
to determine the jitter tolerance at a partic-
ular transmit amplitude and frequency
point. (not selectable if Jitter Mode is
“JTF”.)
Manual Jitter Settings (only
selectable if the Test Mode
is “Terminate”.)
Specify the following:
– Modulation: On or Off
– Jitter Tx Frequency
(Hz)
– Jitter Tx Amplitude (UI)
NOTE:
Manual jitter is the default jitter mode.
It begins running when you enter the jitter
application.
Interface Settings
Specify the Tx Clock Source, TX Line Code,
and Rx Line Code as described in
interface settings” on page 30
Frame Settings
Specify the Framing, Payload, Time Slots,
and Sa bits as described in
.
Pattern Settings
Specify the pattern as described in
ing a BERT pattern” on page 33
Error/Alarm Settings
Specify the settings as described in
ing Error/Alarm settings” on page 35
Performance Settings
Specify the settings as described in
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......