![JDS Uniphase SmartClass E1 Скачать руководство пользователя страница 47](http://html2.mh-extra.com/html/jds-uniphase/smartclass-e1/smartclass-e1_user-manual_3644301047.webp)
Chapter 4
E1 Testing
Specifying test application settings
SmartClass E1 Tester User’s Guide
31
3
If you need to specify other settings for the test, press
Cancel
to return to
the Configuration menu.
The interface settings are configured.
Specifying E1 framing
settings
Before transmitting E1 traffic, you can specify the framing format and payload
of the traffic you want to transmit.
To specify E1 framing settings
1
If you haven’t already done so, launch an E1 application (see
an E1 test application” on page 28
).
2
On the Configuration menu, select
E1 Frame Settings
, and then specify
values for the settings listed below:
Tx Clock
Select one of the following:
–
Internal
–
Rx1
–
Rx2
–
Ext. BNC
NOTE:
If timing is lost, the SmartClass reverts
to internal timing.
Tx Clk Offset (ppm)
Enter a value, from
-100
through
100
ppm, to
indicate the offset frequency generated by the
2048 kbit/s internal clock.
To specify negative numbers, press the
#
key.
To delete a single character, press the down
arrow key.
Slip Reference
Select one of the following slip reference
options:
–
Rx2
–
Ext. BNC
Setting
Parameter
Setting
Parameter
Framing
Select the framing format for the signal:
–
PCM31C
–
PCM31
–
PCM30C
–
PCM30
–
Unframed
Payload
Select the payload:
–
Bulk
:
full E1 circuit
–
n x 64k
: individual timeslot(s) from an E1
circuit
Содержание SmartClass E1
Страница 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 2: ......
Страница 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Страница 6: ...iv SmartClass E1 Tester User s Guide...
Страница 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Страница 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Страница 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Страница 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Страница 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Страница 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Страница 143: ......