Commands 61
REPLACE
Command packet
Description
Replace output channel with factory spare
Parameters
Switch, Output, Spare
Parameter
Description
Switch (unsigned eight-bit)--switch number
Output (unsigned eight-bit)--channel number to be replaced
Spare (unsigned eight-bit)--factory spare number
OPCODE
Length
Parameters
0x33
0x3
U8 Switch, U8 Output, U8 Spare
Switch (unsigned eight-bit)--Logical switch number (1 to 4)
Output (unsigned eight-bit)--The replaced output channel (1 to 200)
Spare (unsigned eight-bit)--The factory spare number used for the replace-
ment (1 to 200)