Chapter 7
Interpreting Test Results
Copper results
56
SmartClass ADSL/Copper Tester User’s Guide
Normal resistance should be at least 5 M
Ω
; lower values indicate the presence
of faults.
describes the resistance result.
Distance to short
This result measure the distance to the short. A resistance measurement of
4 k
Ω
or less typically indicates a short. For values greater than 4 k
Ω
, this func-
tion is disabled.
describes the distance to short result.
Leakage
Leakage is a resistance measurement using higher voltage.
describes the leakage result.
Opens/Capacitance
You measure opens/capacitance to:
– measure total electrical loop length (includes length of bridged taps).
– find wet sections, bridged taps or open faults.
Table 23
Resistance result specifications (no ambient)
Range (
Ω
)
Resolution (
Ω
)
Accuracy
0 to 999
1
2% ± 2.5
Ω
1.0K to 9.99K
10
2%
10.0K to 99.9K
100
2%
100.0K to 999K
1K
2%
1.0M to 9.9M
10K
6.5%
10.0M to 100M
100K
6.5%
Table 24
Distance to short result specifications
Range (feet)
Resolution
Range (meters)
Resolution
0 to 3000
1 foot
0 to 999
3 meters
3000 to 30,000
100 feet
1000 to 10,000
30.5 meters
Table 25
Leakage result specifications (no ambient)
Range (
Ω
)
Resolution (
Ω
)
Accuracy
0 to 999
1
2% ± 2.5
Ω
1.0K to 9.99K
10
2%
10.0K to 99.9K
100
2%
100.0K to 999K
1K
2%
1.0M to 9.9M
10K
6.5%
10.0M to 100M
100K
6.5%
Содержание SC-ADSL-A
Страница 1: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Страница 2: ......
Страница 3: ...SmartClass ADSL Tester Copper Tester and ADSL Copper Tester User s Guide...
Страница 6: ...iv SmartClass ADSL Copper Tester User s Guide...
Страница 14: ...About this Guide Conventions xii SmartClass ADSL Copper Tester User s Guide...
Страница 26: ...Chapter 2 Quick Tour Using the keypad 12 SmartClass ADSL Copper Tester User s Guide...
Страница 32: ...Chapter 3 Instrument Settings Restoring factory defaults 18 SmartClass ADSL Copper Tester User s Guide...
Страница 48: ...Chapter 5 Copper Testing Calibrating the unit 34 SmartClass ADSL Copper Tester User s Guide...
Страница 58: ...Chapter 6 Configuring Tests Loading a configuration 44 SmartClass ADSL Copper Tester User s Guide...
Страница 74: ...Chapter 7 Interpreting Test Results Saving results 60 SmartClass ADSL Copper Tester User s Guide...
Страница 84: ...Chapter 9 Troubleshooting Resolving problems 70 SmartClass ADSL Copper Tester User s Guide...
Страница 89: ......