CLEANING THE VALIDATOR HEAD (MONTHLY/12,000 CYCLES)
1. Remove the iVIZION Validator Head (refer to
Figures 1 and 2
) from the
Transport Unit. To do so:
a). Press the green release (“PUSH”) button on the front of the Validator Head.
b). Pull the Validator Head off and away from the Transport Unit.
2. Open the Validator Head cover by pressing the green-colored release latches on
the left and right sides (refer to
Figure
2
).
3. Use a clean, lint-free Micro-Fiber cloth (dampened with cleaning solution) to
wipe off any dirt and stains from the surfaces of the Imaging and Optical Sensors.
4. Use a clean, dry Micro-Fiber cloth to perform a second wipe-down of the Bill
Path area, to remove any excess cleaning solution, moisture, residue or haze from
the Imaging and Optical Sensor Lenses. Make sure the entire Bill Path is free of
any smudges, streaks or residue.
NOTE: Be sure to wipe down the entire Bill Path in both the upper and lower
sections of the Validator Head.
Figure 2
iVIZION Validator Head
GENERAL (ANNUAL/144,000 CYCLES)
1. After cleaning, reassemble the iVIZION Validator Head and the Transport Unit,
so that the iVIZION Unit is fully assembled.
2. Calibrate the iVIZION Unit.
3. Using the JCM Tool Suite application, initialize the iVIZION Statistics.
4. If a repair or firmware change is not required, then the iVIZION Cleaning and
Preventive Maintenance procedure is complete. The iVIZION Unit may be
returned to service.
NOTE: Refer to Section 6 of the iVIZION Operation and Maintenance Manual
(JCM P/N 960-100929R) for calibration instructions.
NOTE: Initialization resets the performance numbers to Zero (0) and stores
the date from the PC on the iVIZION Unit for future reference.
NOTE: Repeat the Monthly, 6 Month and Annual Procedures for the next
Preventive Maintenance cycle.