6 - 7
CHAPTER 6
Trouble Shooting
4-4
Communication between acceptor and host controller cannot be established.
Check by the procedure
mentioned in above (2)
whether the software in the
flash ROM or EPROM is
correct.
Install (download) correct software to
the flash ROM, or replace with a
correct EPROM.
Check by Performance
Tests 7-5-4 "Acceptor I/F
Output" and 7-5-5 "Acceptor
I/F Input".
(N)
(N)
(Y)
Replace the I/F cable of acceptor.
Replace CPU board.
==>
Calibration
.[*2]
(Y)
[*2] Refer to CHAPTER 7-2
for Calibration procedure.
4-5
Bill is rejected or the bill acceptance rate is low. Green LED blinks.
Check whether ROM is
complied with the currency
of the bill.
Install (download) the correct
software to the flash ROM, or
replace with a correct EPROM.
Clean the tray.
==>
Calibration
.[*2]
(N)
(N)
(N)
(Y)
Check the
connection of
harness from
CPU board to the
sensor board.
Replace the harness
connected to sensor board.
==>
Calibration
.[*2]
(N)
Replace sensor board.
==>
Calibration
.[*2]
Replace CPU board.
==>
Calibration
.[*2]
(Y)
[*2] Refer to CHAPTER 7-2
for Calibration procedure.
Bill is rejected.
The acceptance
rate is low.
Содержание EBA-30-SD3
Страница 5: ...1 5 CHAPTER 1 Product Name Specifications 4 Component Names I F Connector External Display Connector...
Страница 10: ...1 10 CHAPTER 1 Product Name Product Specifications 8 Outside Dimensions 8 1 EBA 3x SD3 without faceplate...
Страница 12: ...1 12 CHAPTER 1 Product Name Product Specifications 8 2 EBA 3x without faceplate...
Страница 13: ...1 13 CHAPTER 1 Product Name Specifications 8 2 EBA 3x with faceplate...