6 - 5
CHAPTER 6
Trouble Shooting
When EBA is unable to accept a bill, LEDs on CPU board blink.
The error status can be determined by the blinking pattern and the number of blinks.
3-1
Bill is not accepted
Red LED blinks, indicating malfunction in the EBA operations.
Check the number of blinks on the red LED, and see Error Code List (Malfunction) on page 6-11.
3-2
Bill is rejected after being accepted
Green LED blinks, indicating the problem on the acceptor’s sensor portion.
Check the number of green LED blinks, and see Error Code List (Rejection) on page 6-12.
3. Error Classification (Malfunction or Rejection)
4. Trouble Shooting
The troubles are mainly categorized into the following 7 conditions:
(1) The power of EBA cannot be turned on.
(2) Test mode cannot be started.
(3) LED on the illuminated bezel does not light.
(4) Communication from acceptor to host controller cannot be established.
(5) Bill is rejected or acceptance rate is low.
(6) Bill transport is not smooth.
(7) Bill is not accepted.
4-1
The power is not turned on
Check cable connection
between EBA and power
supply(host controller).
Replace CPU board.
==> Calibration.[*2]
Properly connect the cables.
(N)
(Y)
Содержание EBA-30-SD3