3-1 To perform the bill identification operation test, first set the acceptor to the test mode
standby status. Set the DIP switches of EBA-1 0/41 0 and VM-450 as shown in the figure
below. Make sure to turn off VM-450 before changing the DIP switch
3 Bill Identification Operation Test Procedure
3-2 When you turn on the power of VM-450, the BSY LED lights and "_000__ 00" will
appear on the segment display.
At this time, the DIP switch next to the LED of EBA will light.
This is called the best mode standby status. You can perform operation test in this status.
VM -450 currency type signal indication
LED light
VEND 1
Currency type
VM - 450
BSY VEND1 VEND2 VEND3
Currency type 1
Currency type 2
Currency type 3
Currency type 4
Currency type 5
Currency type 6
VEND 2
VEND 3
EBA-10/410 DIP switch setting
OFF
OFF
3-3 Executing the identification operation tests
Set the DIP switch of the acceptor as shown in the figure below.
3-4 When you turn off DIP switch No. 1 of the acceptor, the acceptor can receive a
bill and you can confirm the bill receiving rate after the intial operation is
completed.
VM.450 indates that the bill is received and the type of currency is indicated by
means of the VEND1 to VEND3 LED combinations.
bill
completed
SD2 Acceptor with stacker
EBA-10/410 DIP switch setting
SD2 Acceptor without stacker
EBA-10/410 DIP switch setting