6 Error Code
(1) Error Code ( Malfunction ) List
Slow flash
No. of times LED flashes
Description of error
1
(1) Detected stacker full.
(2) Operation of the insertion slot unit is lagging.
2
(1) Insertion slot unit operation error.
(2) No signal is sent from the stacker home position sensor.
(3) No signal is sent from the stacker encoder.
3
(1) Bill stays in the stacker feed route.
(2) Feed operation of the stacker is disabled
4
(1) Bill stays in the acceptor.
5
Acceptor feed motor speed error.
6
(1) Acceptor motor was started but does not rotate.
(2) Acceptor motor was stopped but does not stop.
(3) No signal is sent from the acceptor encoder sensor.
7
Reserved.
8
Reserved.
9
(1) PB unit motor was started but does not rotate.
(2) PB unit motor was stopped but does not stop.
(3) No signal is sent from the home sensor the PB unit.
10
Reserved.
11
Stacker board extension port error
12
Sensor turned on at a timing impossible in normal operation.
(3) Error Code ( Rejecting a bill ) List
Fast flash
No. of times LED flashes
Description of error
1
Bill was inserted at crooked angle.
2
Magnetic sensor pattern error.
3
Bill stays in the acceptor feed route.
4
Photo sensor error 1.
5
Bill feed error.
6
Judgement error.
7
Photo sensor error 2.
8
Bill Photo sensor error 3.
9
Receiving inhibited bill was rejected.
10
Reject signal was input.
11
Lever sensor has detected an error.
12
Back sensor has detected an error.
13
Incorrect length bill.
14
Photo sensor error 4.
15
Photo sensor error 5.