background image

11. Unplug the existing Bill

Validator harness.

12. Attach the new harness to

the Bill Validator connectors
(see Figure 5).

Figure 5

13. Secure the wire harness to

the reel shelf.

Troubleshooting

When there is a loss of communication between the Bill Validator
and the machine, a flashing blue icon of an ambulance blinks on
the front of the bezel and the Bill Validator shuts down. If

 one of

the four red icons lights up with the flashing ambulance,  it indi-
cates a specific problem and the Bill Validator will shut down.

Error Indicators

1. Key

Problem with the cash box. Someone with access to the cash
box must handle this problem.

2. Crossed Circle

ROM verification error or a jammed motor. The Bill Validator will
have to be returned to the shop for repairs.

Activation

 When the ID-023/024 SENTRY bezels are received from the factory
and installed, the denomination/barcode lights will not operate upon
initial powerup of the units. The SENTRY set-up Tool, Part No. 550-
100175 can quickly and easily program the bezel to accept the
approrpiate denominations. Contact your JCM Sales Representative to
order the kit, or use the following procedure. The installer must insert
the appropriate bill denominations and barcode coupon into the
SENTRY to program the onboard EEPROM. This activates the
appropriate denominations/barcode coupon lights for normal operation.