manualshive.com logo in svg
background image

 

TRAIL COUNTER 

FIELD MANUAL

 

TTC-4420 

 
 

 

 

Version 6.00   1/08

 

 
 

 
 

 

Version 1.00   1/96 
Version 2.00   9/00 
Version 3.00 11/01 
Version 4.00   3/03 
Version 5.00   7/03 

 

 
 

 

Diamond Traffic Products 
76433 Alder Street 
Oakridge, OR   97463 

[email protected]

  

 
 
 
 
 
 
 

Содержание TTC-4420

Страница 1: ...ELD MANUAL TTC 4420 Version 6 00 1 08 Version 1 00 1 96 Version 2 00 9 00 Version 3 00 11 01 Version 4 00 3 03 Version 5 00 7 03 Diamond Traffic Products 76433 Alder Street Oakridge OR 97463 sales dia...

Страница 2: ......

Страница 3: ...affic on forest trails The original TCS 90 design was completed in 1972 at the Missoula Equipment Development Center USDA Forest Service Missoula Montana and was manufactured according to the U S Depa...

Страница 4: ...signal is We recommend signal strength of 60 or above The Trail Counter works as follows the scanner sends a beam of pulsed infrared light to the reflector which reflects the beam back to the scanner...

Страница 5: ...fe The TTC 4420 collects data in hourly intervals and the grand total All data can be read off the counter display using the magnet to key up data Optionally an RS 232 serial port can be installed tha...

Страница 6: ...eries in correct orientation with positive battery terminal to positive holder terminal In weather colder than 10 degrees F call Diamond Traffic for advice on lithium cold weather batteries Battery Re...

Страница 7: ...is protected from the sun and weather will produce better results However the infrared receiver does incorporate a filter lens to remove unwanted light frequencies On Site Installation The following g...

Страница 8: ...zinc batteries 4 Hold the reflector in the beam thus canceling the tone and gradually move toward the desired reflector location NOTE THE TONE GENERALLY CANNOT BE CANCELLED WHEN THE REFLECTOR IS HELD...

Страница 9: ...lay the name of the counter and the internal firmware version and release date TTC 442X V1 00 10 1 01 Wait a few seconds for the next screen Note If a Datahog is connected at any time from this point...

Страница 10: ...is no data in the memory wait a few seconds for next screen If there is data in memory magnetically activate yellow dot to read it or red dot to skip to TOTAL COUNT screen Notes Manual Data The displa...

Страница 11: ...ful if you want to hear the Siren without restarting collection When the Siren is enabled an asterisk appears in the top right corner When collecting is active the Stop changes to the current total co...

Страница 12: ...ow To Read Data Counter is capable of recording one hour interval counts of up to 420 days touch magnet to yellow dot on side of counter display will show grand running total with first touch and the...

Страница 13: ...ter for optimal results The counter will also collect test counts when the beam is broken for verification that the unit is working You must block the beam for about 1 6 of a second or more Easiest me...

Страница 14: ...lem Send unit to Diamond Traffic Products 76463 Alder Street Oakridge OR 97463 If our inspection shows that problem was caused by defective material or workmanship within the limitations of the warran...

Отзывы: