5.

 

Verify the installation. 

Perform a complete operation from both sides of the door ensuring that activation of the control panel is correct on 
the desired coverage area, and ensuring that you can not activate the door without seeing it. 
Check that the motor wiring is correct, and that the semi-automatic mode works in the open way (and not in the close way). 

 

 

OPERATING 

Upon receiving a code, the equipment checks whether it is in its memory, activating the opening or closing of the door. 

 
-

 

In dead man operating, only it is activated inside the coverage area. 
If  the  dead  man  transmitter  is  not  inside  the  coverage  area,  the  led  will  flash  and  the  equipment  will  emit  three  acoustic 

signals.  

-

 

In  semi-automatic  operating,  the  open  pushbutton  opens  in  semi-automatic  mode  (2  minutes),  without  being  inside  the 
coverage  area.  The  close  pushbutton  will  stop  the  motor  at  any  distance,  and  then  can  close  the  door  in  dead  man  mode, 

provided it is operated from inside the coverage area.

 

-

 

During the closing movement, if the dead man transmitter leaves the coverage zone, the door stops.

 

 

 

RESET TOTAL 

In  programming  mode,  the  programming  button  is  held  down  and  a  short-circuit  on  MR  jumper  is  done  for  over  10  sec.  The 
equipment will issue 10 short acoustic warning signals followed by others at a faster pace to indicate that the operation has been 
successful. The equipment is now in programming mode. The pilot programming light will also follow the acoustic indications by 

flashing. 
After  10  seconds without programming  or  quickly  pressing  the  programming button,  the  equipment  will exit programming  mode, 
issuing two 1 sec. acoustic signals. 

 

BATTERY LIFE (VALUE FOR GUIDANCE PURPOSES)  

 

Manoeuvres / day 

Manoeuvre duration (s) 

20 

16 

12 

15 months 

18 months 

24 months 

36 months 

72 months 

144 months 

10 

8 months 

9 months 

12 months 

18 months 

36 months 

72 months  

15 

5 months 

6 months 

8 months 

12 months 

24 months 

48 months 

20 

4 months 

5 months 

6 months 

9 months 

18 months 

36 months 

25 

3 months 

4 months 

5 months 

7 months 

15 months 

29 months 

30 

2 months 

3 months 

4 months 

6 months  

12 months 

24 months 

 

USE OF THE RECEIVER-PANEL 

This receiver-panel is designed for use as a remote control for automatic doors. 
Its use is not guaranteed for directly activating any other equipment different to that specified. 
The manufacturer reserves the right to modify equipment specifications without prior notice. 

 

IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION 

 

Disconnect the power supply whenever you proceed 

to the installation or repair of the control panel. 

· Disconnect the power supply before handing the equipment. 

· Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as locks that is not necessary 
for the automatic operation. 
· Before installing the panel, check that the door is in good mechanical condition, correctly balanced and that it opens and closes 

correctly. 
· Install the manual unlocking device at a height lower than 1.8m. 

· Install any permanent control next to the door away from any moving part and at a minimum height of 1.5m. 
· An easily accessible disconnection device must be fitted to the wiring for permanently connected equipment. It is wise for this to be 
an emergency switch. 

· Check that there is a security measure that protects the engine when reach the final point (open and closed). 
· Check that you can not activate the door without seeing it. 
· Check that the semi-automatic mode works in the open way (and not in the close way). 

· This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained operator. 
· To connect the power supply and motor wiring, 3.8 mm2 section terminals must be used. 
·  Use protective goggles when handling the equipment.   

· Fuses must only be handled when the appliance is disconnected from the mains. 