Part No. 960-100919R_Rev. 1

© 2017 JCM American Corporation

6

March, 2017

JCM Training Overview

Taiko™ Banknote Validator

Lecture Notes

LED P

ATTERN

 S

ELECTION

 S

ETTINGS

The Bezel LED oscillating Pattern Color can be changed to oscillate between 
two preset changing Color patterns.
To select and set Color Pattern #1, proceed as follows:

1. Remove power from the Taiko

 Unit.

2. Set DIP Switches #1, #2 and #7 to ON.

3. Reapply power to the Taiko

 Unit.

4. When the White LED begins to flash, turn DIP Switch #1 OFF. 

The selected pattern is now set. 

5. Remove power from the Taiko

 Unit, reset the DIP Switches to their normal 

operating positions, and reapply power to the Unit.

To select and set Color Pattern #2, proceed as follows:

1. Remove power from the Taiko

 Unit.

2. Set DIP Switches #1, #3 and #7 to ON.

3. Reapply power to the Taiko

 Unit.

4. When the White LED begins to flash, turn DIP Switch #1 OFF. 

The selected pattern is now set. 

Remove power from the Taiko

 Unit, reset the DIP Switches to their normal operating 

positions, and reapply power to the Unit.

Содержание Taiko PUB-7

Страница 1: ... No 960 100919R_Rev 1 March 2017 2017 JCM American Corporation JCM TRAINING OVERVIEW Taiko Banknote Validator PUB 7 11 Phone 800 683 7248 702 651 0000 Fax 702 651 0214 support jcmglobal com www jcmglobal com ...

Страница 2: ... Features 5 Denomination Settings 5 Accept Mode 5 Inhibit Mode 5 LED Pattern Selection Settings 6 Cleaning the Unit 7 Calibration 8 Entering Test Mode 9 Functional Tests 9 Aging Test Error Codes 11 Error Codes Bill Acceptance 13 Sensor Locations 15 Downloading Software 16 PC Software Loading 16 BlueWave 2 0 Software Update 16 Cloning Software 17 Malfunction Errors 18 Red LED Error Code Definitions...

Страница 3: ... Sensor Types Unit Currency Sensors Available PUB 7 Optical Transparency and Reflective PUB 11 Optical Transparency Reflective and Magnetic Figure 1 Taiko PUB 7 11 Primary Component Parts A Bezel B Bezel LED C Upper Guide Lid D Lower Guide Lid E Lower Lid Lock Release Buttons F Banknote Insertion Slot G Banknote Exit Slot H Interface Connector I Maintenance Connector J Faceplate Installation Guide...

Страница 4: ... Setting Mode 2 OFF 1 time scan without validation retry ON 2 time scan mode with validation retry 3 OFF When Pulse I F Mode depends on enable disable signal ON When Pulse I F Mode always enabled 4 OFF 1 time Spin Mode 1 Drum Rotation Cycle ON 5 time Spin Mode 5 Drum Rotation Cycles Anti Fishing Prevention 5 Serial I F Mode DIP Switch 8 OFF Pulse I F Mode DIP Switch 8 ON 6 7 8 OFF Serial I F Mode ...

Страница 5: ... is now enabled 6 Continue to insert each desired Banknote denomination that is to be accepted 7 When done remove power from the Taiko Unit reset the DIP Switches to their normal operating positions and reapply power to the Unit To disable the acceptance of particular Banknote denominations use the following Inhibit Mode Procedure The default setting is to accept all Banknotes programmed in the ex...

Страница 6: ...ower to the Taiko Unit 4 When the White LED begins to flash turn DIP Switch 1 OFF The selected pattern is now set 5 Remove power from the Taiko Unit reset the DIP Switches to their normal operating positions and reapply power to the Unit To select and set Color Pattern 2 proceed as follows 1 Remove power from the Taiko Unit 2 Set DIP Switches 1 3 and 7 to ON 3 Reapply power to the Taiko Unit 4 Whe...

Страница 7: ...em Use a mild soap and water solution ONLY with a lint free cloth Wipe the lenses drive rollers and Banknote transportation path clean Remove the Lower Guide and clean any observable material build up from the idler rollers and the lower area of the Unit Open the Upper Guide and clean any observable material build up from the idler rollers and the upper area of the Unit NOTE Alcohol Solvents or Ci...

Страница 8: ...hing WHITE 5 Set DIP Switch 1 to OFF 6 Confirm that the Front Panel LED is steady Lit GREEN 7 Insert the KS 70 Reference Paper It will feed in automatically and the GREEN LED will flash 8 Set DIP Switch 8 to OFF The YELLOW LED will light and the Reference Paper will eject the GREEN LED will then flash 9 Remove the Reference Paper from the Unit 10 Set DIP Switch 8 to ON The YELLOW LED will light st...

Страница 9: ...h settings Table 3 Taiko TEST DIP Switch Settings Setting Function SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 DIP Switch Test ON ON ON ON ON ON ON ON Transport Motor Forward Rotation Test ON OFF OFF OFF OFF OFF OFF OFF Transport Motor Reverse Rotation Test ON ON OFF OFF OFF OFF OFF OFF Aging Test ON ON OFF ON OFF OFF OFF OFF Solenoid Test ON ON ON ON OFF OFF OFF OFF Acceptance Test ON OFF OFF OFF ON OFF OFF ...

Страница 10: ...est 2 proceed as follows 1 Set DIP Switch 1 and 2 ON and apply power to the Taiko Unit 2 Set DIP Switch 1 OFF The following indications will occur If the BLUE LED begins Flashing the Reverse Motor rotational speed is cor rect If the RED LED is flashing the Reverse Motor speed is either too fast or too slow Set DIP Switch 1 to ON to stop the Reverse Motor Rotational Test Test No 3 Aging Test To per...

Страница 11: ...Transit Sensor 5 Entrance Solenoid Sensor 6 Exit Solenoid Sensor 7 VEND Lever Sensor 8 Encoder Sensor 1 Right IR Penetration Upper to Lower 2 Left IR Penetration Upper to Lower 3 Right Red Penetration Upper to Lower 4 Left Red Penetration Upper to Lower 5 Right NIR Penetration Upper to Lower 6 Left NIR Penetration Upper to Lower 7 Right Blue Penetration Upper to Lower 8 Left Blue Penetration Upper...

Страница 12: ...f the Exit Solenoid fails to de energize the RED LED flashes 4 times 3 Set DIP Switch 1 ON to stop the Solenoid Test Test No 5 Acceptance Test To perform Diagnostic Test No 5 proceed as follows 1 Set DIP Switches 1 and 5 to ON 2 Set DIP Switch 1 OFF to start the Acceptance Test 3 Insert Banknotes The following indications will occur The GREEN LED will flash a count for the denomination of the Bank...

Страница 13: ...LOW LED will flash a specific code sequence Table 5 lists the various RED or YELLOW LED Error Codes possible Table 5 LED Flash Error Codes Flash No and Color Error Indicated 2 ROM Error 3 Bill Jam inside Acceptor 4 Bill Remaining in the Transport Path 5 Adjustment Error 6 Motor Error 8 Entrance Solenoid Error 9 Exit Solenoid Error 12 Sensor Operating with Abnormal Timing 1 Skewed Bill Insertion Re...

Страница 14: ...est Test No 7 Exit Flapper Test To perform Diagnostic Test No 7 proceed as follows 1 Set DIP Switches 1 2 4 and 5 ON 2 Set DIP Switch 1 OFF to start the Exit Flapper Test The following indications will occur The BLUE LED lights each time the Solenoid is energized The RED and BLUE LEDs alternately light if a Sensor or Solenoid Error occurs Set DIP Switch 1 ON to stop the Exit Flapper Test Sensor Te...

Страница 15: ...ious Sensor Types Table 6 Taiko Sensor Types Symbol Sensor Type a Side Sensor b Validation Sensor c Entrance Flapper Sensor d Entrance Sensor e Side Sensor Prism f Upper Transport Sensor g Entrance Sensor Prism h Bend Lever Sensor i Upper Transport Sensor Prism j Lower Transport Sensor k Lower Transport Sensor Prism f e b g d a h i Magnetic Head a b c d g e Magnetic Head Roller j k PUB 11 Figure 2...

Страница 16: ...download is complete and the CRC is verified the BLUE LED will light The download is now complete BLUEWAVE 2 0 SOFTWARE UPDATE To update BlueWave 2 0 Software proceed as follows 1 Ensure the PUB software file is located in the DOWNLOAD folder on the SD Card 2 Insert the SD Card into the BlueWave 2 0 Handheld Download Tool 3 Connect the BlueWave 2 0 Download Tool to the PUB EBAAdapter 4 Connect the...

Страница 17: ...enance Connector Ports on each Taiko Unit 2 On the Master Unit turn DIP Switches 1 2 7 and 8 ON 3 On the Slave Taiko Unit turn DIP Switches 1 7 and 8 ON 4 Connect an external power supply to the Master Taiko Unit 5 The Front Panel LED of the Master Taiko Unit will flash WHITE 6 The Front Panel LED of the Slave Taiko Unit will flash GREEN 7 On the Master Taiko Unit turn DIP Switch 1 OFF and the clo...

Страница 18: ...LED will flash a code sequence indicating the cause of the error Table 7 lists the RED Error Code flash sequence definitions displayed by the Taiko Unit s Front Panel LED Indicator Table 7 Red LED Error Code Flash Definitions Red Flashes Error Indicated 2 ROM Error 3 Bill Jam inside Ejection Slot 4 Bill remains inside Transport path 5 EEPROM Read Write Error 6 Motor Error 8 Entrance Solenoid Error...

Страница 19: ...pply to Taiko EDP 127527 400 100589RA Cloning Cable Brown Maintenance Connectors EDP 124528 701 100104R PUB UAC Kit 400 100543R PUB RS232 Harness Photo Coupler RS 232 Conversion PCB in the Harness 400 000151R PUB 12V Power Harness 400 000087R BlueWave 2 Harness Brown Connector 400 000207R BlueWave 2 Harness Black Connector 501 100252R JCM Waffletechnology Banknote Validator Cleaning Card Thank You...

Страница 20: ...registered trademark of JCM American Corporation All other product names mentioned herein may be registered trademarks or trademarks of their respective companies Furthermore and are not always mentioned in each case throughout this publication JCM American Corporation has been accredited as an Authorized Provider by the International Association for Continuing Education and Training IACET PERSONA...